Dual Independent Oval Pads (DIOP) Platform for Testing Wide Range of Complex Reservoirs

Wireline testing technology has developed over many years and continues to evolve as applications extend to more complex reservoirs. The utilization of traditional wireline tools for reservoir pressure and sampling faces significant challenges to capture high quality samples in the presence of complex fluid dynamics in low permeability to tight reservoirs. These challenging reservoirs, often characterized by suboptimal reservoir quality, pose difficulties for evaluation, leading to the inadvertent neglect of substantial hydrocarbon reserves. Testing has often been limited by either the surface area coverage between probes and formation requiring significant movement to land good quality spots or the high differential pressure that results due to increasing flow rates with smaller probes. This study aims to address these challenges by introducing a new probe to the field of formation testing. The dual independently- deployed oval pads have a flow area from 30 to 54 squared inches and can operate with up to 8000 psi differential pressure. This probe enables testing of low to moderate mobility reservoirs and extends capabilities to testing depleted formations under high differential pressure conditions. Furthermore, it can greatly increase chances of success for evaluating heavy oil and unconventional reservoirs by significantly minimizing drawdown pressure compared to conventional formation testers. The emergence of Dual Independent Oval Pads (DIOP) allows reservoir engineers to get desired dynamic information over a broader range of challenging reservoirs in less time. Tool flexibility in drawdown rate and volume coupled with DIOP results in a higher rate of success over ranges of permeability, fluid viscosity, and reservoir laminations. Furthermore, DIOP is designed with independent deployment of the dual pads minimizing the possibility of not sealing across rugose boreholes. This work presents some field examples of testing and sampling using Dual Independent Oval Pads to pump out across different ranges of reservoir mobilities. An increase in pumping rate with significant reduction in drawdown pressure was observed compared to performance with the conventional dual probe configuration in similar reservoir environments.

Authors

Publication Details

Published
2025-05-17
DOI
https://doi.org/10.30632/spwla-2025-0008
Primary Topic
Hydraulic Fracturing and Reservoir Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual Independent Oval Pads (DIOP) Platform for Testing Wide Range of Complex Reservoirs

Tony van Zuilekom, M. S. Iyer, Moutaz Abdein, Gibran Hashmi et al.
Hydraulic Fracturing and Reservoir Analysis
article

Dual Independent Oval Pads (DIOP) Platform for Testing Wide Range of Complex Reservoirs

Tony van Zuilekom, M. S. Iyer, Moutaz Abdein, Gibran Hashmi, Sarvagya Parashar, Rosemary Gales, Carlos Eduardo
article en

Abstract

Wireline testing technology has developed over many years and continues to evolve as applications extend to more complex reservoirs. The utilization of traditional wireline tools for reservoir pressure and sampling faces significant challenges to capture high quality samples in the presence of complex fluid dynamics in low permeability to tight reservoirs. These challenging reservoirs, often characterized by suboptimal reservoir quality, pose difficulties for evaluation, leading to the inadvertent neglect of substantial hydrocarbon reserves. Testing has often been limited by either the surface area coverage between probes and formation requiring significant movement to land good quality spots or the high differential pressure that results due to increasing flow rates with smaller probes. This study aims to address these challenges by introducing a new probe to the field of formation testing. The dual independently- deployed oval pads have a flow area from 30 to 54 squared inches and can operate with up to 8000 psi differential pressure. This probe enables testing of low to moderate mobility reservoirs and extends capabilities to testing depleted formations under high differential pressure conditions. Furthermore, it can greatly increase chances of success for evaluating heavy oil and unconventional reservoirs by significantly minimizing drawdown pressure compared to conventional formation testers. The emergence of Dual Independent Oval Pads (DIOP) allows reservoir engineers to get desired dynamic information over a broader range of challenging reservoirs in less time. Tool flexibility in drawdown rate and volume coupled with DIOP results in a higher rate of success over ranges of permeability, fluid viscosity, and reservoir laminations. Furthermore, DIOP is designed with independent deployment of the dual pads minimizing the possibility of not sealing across rugose boreholes. This work presents some field examples of testing and sampling using Dual Independent Oval Pads to pump out across different ranges of reservoir mobilities. An increase in pumping rate with significant reduction in drawdown pressure was observed compared to performance with the conventional dual probe configuration in similar reservoir environments.

Openalex Percentile: Top 71%
Hydraulic Fracturing and Reservoir Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dual Independent Oval Pads (DIOP) Platform for Testing Wide Range of Complex Reservoirs — Tony van Zuilekom, M. S. Iyer, et al. · (2025) | TGRS Research Map | TGRS