The energy performance gap – a Swedish perspective

Literature reviewsfrom various countries indicate a difference between calculated and measuredbuilding energy use, often known as the ‘energy performance gap’. This articleexplores the existence and magnitude of the energy performance gap in Swedenand identifies possible reasons behind it. A general evaluation of Swedishbuildings showed a median discrepancy between 10–20%. To explore causes,semi-structured interviews were conducted with 28 building energy experts, whoconfirmed the presence of the EPG and identified contributing factors. Theseinclude: (i) insufficient system optimization post-occupancy, (ii) inaccuraciesin input data, particularly hot water circulation losses, (iii) unexpectedoccupant behaviour, (iv) inconsistent energy metering (v) poor communication.Energy simulation was conducted on a case-study to analyze the differentfactors’ impact. The paper highlights potential strategies to mitigate the EPG,including improved commissioning and enhanced feedback during project deliveryand operation. A holistic approach with effective communication is necessaryfor better building performance.

Authors

Institutions

Publication Details

Journal
Journal of Building Performance Simulation
Published
2025-10-09
DOI
https://doi.org/10.1080/19401493.2025.2567993
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The energy performance gap – a Swedish perspective

Akram Abdul Hamid, Pieter de Wilde, Asala Bandak, Athira Sreenivasan
Journal of Building Performance Simulation
Building Energy and Comfort Optimization
article

The energy performance gap – a Swedish perspective

Akram Abdul Hamid, Pieter de Wilde, Asala Bandak, Athira Sreenivasan
article en

Abstract

Literature reviewsfrom various countries indicate a difference between calculated and measuredbuilding energy use, often known as the ‘energy performance gap’. This articleexplores the existence and magnitude of the energy performance gap in Swedenand identifies possible reasons behind it. A general evaluation of Swedishbuildings showed a median discrepancy between 10–20%. To explore causes,semi-structured interviews were conducted with 28 building energy experts, whoconfirmed the presence of the EPG and identified contributing factors. Theseinclude: (i) insufficient system optimization post-occupancy, (ii) inaccuraciesin input data, particularly hot water circulation losses, (iii) unexpectedoccupant behaviour, (iv) inconsistent energy metering (v) poor communication.Energy simulation was conducted on a case-study to analyze the differentfactors’ impact. The paper highlights potential strategies to mitigate the EPG,including improved commissioning and enhanced feedback during project deliveryand operation. A holistic approach with effective communication is necessaryfor better building performance.

Journal of Building Performance Simulation
Lund University (SE)
Openalex Percentile: Top 69%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.