Development of a Fast, Low-Cost, and Green Method to Quantify Allura Red AC Dye in Candies through Digital Images Using a Smartphone

The artificial azo dye Allura Red AC (E129), widely used in candy, may pose health risks, such as hypersensitivity and hyperactivity, underscoring the need for its monitoring and quantification to ensure food safety. This study adapted a traditional sample preparation approach aligned with the principles of green analytical chemistry (GAC) and introduced a low-cost, smartphone-based colorimetric method employing digital image acquisition. The technique enables the simultaneous capture of both the analytical curves and the samples in a single image by using a 3D-printed digital imaging chamber. The data were processed using the RGB color model and analyzed by partial least-squares with REDGIM software. For the adapted UV-vis method, accuracy at two concentration levels ranged from 77.33% ± 1.53 to 98.35% ± 0.07, with a limit of quantification (LQ) of 2.26 × 10<sup>-6</sup> mg mL<sup>-1</sup> and a limit of detection (LD) of 7.47 × 10<sup>-7</sup> mg mL<sup>-1</sup>. For the DIA-RD method, accuracy ranged from 78.04% ± 1.42 to 98.42% ± 0.06, with a LQ of 1.67 × 10<sup>-4</sup> mg mL<sup>-1</sup> and a LD of 5.51 × 10<sup>-5</sup> mg mL<sup>-1</sup>. E129 concentrations in ten candy samples ranged from 7.00 × 10<sup>-4</sup> to 5.16 × 10<sup>-3</sup> mg mL<sup>-1</sup> using the UV-vis method and from 7.33 × 10<sup>-4</sup> to 4.83 × 10<sup>-3</sup> mg mL<sup>-1</sup> using the DIA-RD method, all below the legal limit of 3.0 × 10<sup>-1</sup> mg mL<sup>-1</sup> established by Brazilian and international regulations. The DIA-RD method significantly reduced sample preparation time, enabling data acquisition and processing in 5 min compared to 6 h with the UV-vis method. It complies with GAC principles and shows a strong potential for routine quality control of candy products.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-10-09
DOI
https://doi.org/10.1021/acsomega.5c06279
Primary Topic
Dye analysis and toxicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Fast, Low-Cost, and Green Method to Quantify Allura Red AC Dye in Candies through Digital Images Using a Smartphone

Jandyson M. Santos, Bruna Ramos de Souza Gomes, Maria Eduarda B. Coutinho
ACS Omega
Dye analysis and toxicity
article

Development of a Fast, Low-Cost, and Green Method to Quantify Allura Red AC Dye in Candies through Digital Images Using a Smartphone

Jandyson M. Santos, Bruna Ramos de Souza Gomes, Maria Eduarda B. Coutinho
article en

Abstract

The artificial azo dye Allura Red AC (E129), widely used in candy, may pose health risks, such as hypersensitivity and hyperactivity, underscoring the need for its monitoring and quantification to ensure food safety. This study adapted a traditional sample preparation approach aligned with the principles of green analytical chemistry (GAC) and introduced a low-cost, smartphone-based colorimetric method employing digital image acquisition. The technique enables the simultaneous capture of both the analytical curves and the samples in a single image by using a 3D-printed digital imaging chamber. The data were processed using the RGB color model and analyzed by partial least-squares with REDGIM software. For the adapted UV-vis method, accuracy at two concentration levels ranged from 77.33% ± 1.53 to 98.35% ± 0.07, with a limit of quantification (LQ) of 2.26 × 10<sup>-6</sup> mg mL<sup>-1</sup> and a limit of detection (LD) of 7.47 × 10<sup>-7</sup> mg mL<sup>-1</sup>. For the DIA-RD method, accuracy ranged from 78.04% ± 1.42 to 98.42% ± 0.06, with a LQ of 1.67 × 10<sup>-4</sup> mg mL<sup>-1</sup> and a LD of 5.51 × 10<sup>-5</sup> mg mL<sup>-1</sup>. E129 concentrations in ten candy samples ranged from 7.00 × 10<sup>-4</sup> to 5.16 × 10<sup>-3</sup> mg mL<sup>-1</sup> using the UV-vis method and from 7.33 × 10<sup>-4</sup> to 4.83 × 10<sup>-3</sup> mg mL<sup>-1</sup> using the DIA-RD method, all below the legal limit of 3.0 × 10<sup>-1</sup> mg mL<sup>-1</sup> established by Brazilian and international regulations. The DIA-RD method significantly reduced sample preparation time, enabling data acquisition and processing in 5 min compared to 6 h with the UV-vis method. It complies with GAC principles and shows a strong potential for routine quality control of candy products.

ACS OmegaVol. 10(48)
Universidade Federal Rural de Pernambuco (BR)
Openalex Percentile: Top 68%
Dye analysis and toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a Fast, Low-Cost, and Green Method to Quantify Allura Red AC Dye in Candies through Digital Images Using a Smartphone — Jandyson M. Santos, Bruna Ramos de Souza Gomes, et al. · ACS Omega (2025) | TGRS Research Map | TGRS