Postoperative Monitoring by Near-Infrared Spectroscopy in Transferred Free Tissue

1, 2). Near-infrared spectroscopy (NIRS) is a noninvasive, sensitive, and reliable method increasingly used for postoperative monitoring.Several types of NIRS instruments are commercially available, and each instrument has slight differences in the measurement algorithms.A Toccare device (Astem, Tokyo, Japan) was used in this study.This device measures regional oxygen saturation (rSO2) and total hemoglobin index (T-HbI), which indicates the total Hb concentration.The device detects 2 wavelengths (770 and 830 nm) with 2 detectors (6 and 8 mm away from the light source); the tissue penetration depth of near-infrared light can be up to 5 mm subcutaneously, with a sensor size of < 1 cm 2 3) .The system can be monitored even when the flap size is small or when the flaps are placed in the

Authors

Institutions

Publication Details

Journal
International Journal of Surgical Wound Care
Published
2025-10-09
DOI
https://doi.org/10.36748/ijswc.25-00010
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Postoperative Monitoring by Near-Infrared Spectroscopy in Transferred Free Tissue

Nobuaki Ito, Tomoyuki Fujita, Hiroshi Ito, Michikazu Nakai
International Journal of Surgical Wound Care
Optical Imaging and Spectroscopy Techniques
article

Postoperative Monitoring by Near-Infrared Spectroscopy in Transferred Free Tissue

Nobuaki Ito, Tomoyuki Fujita, Hiroshi Ito, Michikazu Nakai
article en

Abstract

1, 2). Near-infrared spectroscopy (NIRS) is a noninvasive, sensitive, and reliable method increasingly used for postoperative monitoring.Several types of NIRS instruments are commercially available, and each instrument has slight differences in the measurement algorithms.A Toccare device (Astem, Tokyo, Japan) was used in this study.This device measures regional oxygen saturation (rSO2) and total hemoglobin index (T-HbI), which indicates the total Hb concentration.The device detects 2 wavelengths (770 and 830 nm) with 2 detectors (6 and 8 mm away from the light source); the tissue penetration depth of near-infrared light can be up to 5 mm subcutaneously, with a sensor size of < 1 cm 2 3) .The system can be monitored even when the flap size is small or when the flaps are placed in the

International Journal of Surgical Wound CareVol. 6(4)
University of Miyazaki (JP)
University of Miyazaki Hospital, University of Miyazaki
Openalex Percentile: Top 58%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.