Cooldown and Ramp Test of a Low-Cryogen, Lightweight, Head-Only 7T MRI Magnet

A compact 7.0 T MRI system (C7T) has been successfully constructed, cooled down, and ramped (energized) to 7.01 T at GE HealthCare Technology and Innovation Center. The C7T magnet is designed for a B0-field homogeneity of <1.0 ppm over a 26-cm field-of-view, dedicated for MRI brain imaging. The C7T magnet applies a fully closed-loop cryogenic cooling system which condenses only 12 liters of liquid helium at 4.2 K from high pressure helium gas charged at room temperature. The helium is permanently sealed inside the cooling system even after a quench. This newly developed 7.0 T MRI has similar size and stray magnetic field as a clinical whole-body 3.0 T MRI magnet, it can be easily installed in a 3T scanner bay. This C7T MRI system can greatly improve the access to high performance 7T brain imaging for more patients. The cooldown, ramp and quench protection performance of the compact 7T MRI magnet prototype is reported in this paper.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2025-10-09
DOI
https://doi.org/10.1109/tasc.2025.3619470
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cooldown and Ramp Test of a Low-Cryogen, Lightweight, Head-Only 7T MRI Magnet

Michael Parizh, Mark Vermilyea, Gene Conte, Vijay Soni et al.
IEEE Transactions on Applied Superconductivity
Superconducting Materials and Applications
article

Cooldown and Ramp Test of a Low-Cryogen, Lightweight, Head-Only 7T MRI Magnet

Michael Parizh, Mark Vermilyea, Gene Conte, Vijay Soni, Thomas Foo, Anbo Wu, Seung‐Kyun Lee, Wolfgang Stautner, Desmond Yeo, Yihe Hua, Minfeng Xu, Justin Ricci, Chris Van Epps
article en

Abstract

A compact 7.0 T MRI system (C7T) has been successfully constructed, cooled down, and ramped (energized) to 7.01 T at GE HealthCare Technology and Innovation Center. The C7T magnet is designed for a B0-field homogeneity of <1.0 ppm over a 26-cm field-of-view, dedicated for MRI brain imaging. The C7T magnet applies a fully closed-loop cryogenic cooling system which condenses only 12 liters of liquid helium at 4.2 K from high pressure helium gas charged at room temperature. The helium is permanently sealed inside the cooling system even after a quench. This newly developed 7.0 T MRI has similar size and stray magnetic field as a clinical whole-body 3.0 T MRI magnet, it can be easily installed in a 3T scanner bay. This C7T MRI system can greatly improve the access to high performance 7T brain imaging for more patients. The cooldown, ramp and quench protection performance of the compact 7T MRI magnet prototype is reported in this paper.

IEEE Transactions on Applied SuperconductivityVol. 36(3)
GE Global Research (United States) (US)
Openalex Percentile: Top 73%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cooldown and Ramp Test of a Low-Cryogen, Lightweight, Head-Only 7T MRI Magnet — Michael Parizh, Mark Vermilyea, et al. · IEEE Transactions on Applied Superconductivity (2025) | TGRS Research Map | TGRS