The Importance of Modeling Press‐Fit to Accurately Evaluate Interfacial Micromotion as an Indicator of Primary Stability in Uncemented Arthroplasty

Arthroplasty is most often performed to alleviate pain and restore function in patients with end-stage degenerative joint disease. Uncemented implant fixation is increasingly used in total knee and total ankle arthroplasty. Implantation using interference press-fit is a manufacturer-recommended guideline for achieving stable primary fixation in uncemented applications, which is important to prevent long-term implant failure due to aseptic loosening. However, when evaluating implant-bone interfacial mechanics, many studies have not modeled press-fit implantation. This can lead to gross underestimation of primary implant fixation stability, limiting the clinical applicability of findings. The goal of this paper is to highlight the importance of simulating press-fit implantation when evaluating primary orthopedic implant stability using finite element analysis in uncemented arthroplasty. Experiences gained in modeling press-fit implantation in total knee and total ankle arthroplasty by two different active research groups are shared in this context.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2025-10-09
DOI
https://doi.org/10.1002/jor.70081
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Importance of Modeling Press‐Fit to Accurately Evaluate Interfacial Micromotion as an Indicator of Primary Stability in Uncemented Arthroplasty

Donald D. Anderson, Joshua E. Johnson, Dennis Janssen, Nico Verdonschot
Journal of Orthopaedic Research®
Orthopaedic implants and arthroplasty
article

The Importance of Modeling Press‐Fit to Accurately Evaluate Interfacial Micromotion as an Indicator of Primary Stability in Uncemented Arthroplasty

Donald D. Anderson, Joshua E. Johnson, Dennis Janssen, Nico Verdonschot
article en

Abstract

Arthroplasty is most often performed to alleviate pain and restore function in patients with end-stage degenerative joint disease. Uncemented implant fixation is increasingly used in total knee and total ankle arthroplasty. Implantation using interference press-fit is a manufacturer-recommended guideline for achieving stable primary fixation in uncemented applications, which is important to prevent long-term implant failure due to aseptic loosening. However, when evaluating implant-bone interfacial mechanics, many studies have not modeled press-fit implantation. This can lead to gross underestimation of primary implant fixation stability, limiting the clinical applicability of findings. The goal of this paper is to highlight the importance of simulating press-fit implantation when evaluating primary orthopedic implant stability using finite element analysis in uncemented arthroplasty. Experiences gained in modeling press-fit implantation in total knee and total ankle arthroplasty by two different active research groups are shared in this context.

Journal of Orthopaedic Research®Vol. 44(2)
University of Iowa (US), Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Radboud Institute for Molecular Life Sciences (NL), University of Twente (NL)
Openalex Percentile: Top 55%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.