Feasibility of a UTE Stack‐of‐Spirals Sequence for T<sub>1ρ</sub> Mapping of Achilles Tendinopathy

We analyzed the feasibility of using a UTE stack-of-spirals turbo FLASH (STFL) sequence to measure T<sub>1ρ</sub> relaxation in the Achilles tendon. Six HS (25-31 years) and five AT patients (32-47 years) participated. The study evaluates the clinical utility of the STFL sequence to generate T<sub>1ρ</sub> maps using mono-exponential (ME) and bi-exponential (BE) fitting models. In a phantom experiment, ME-T<sub>1ρ</sub> values and SNR estimated from the STFL sequence are compared with those of the Cartesian turbo FLASH (CTFL) sequence. In human subjects, we evaluate differences in estimated ME (ME-T<sub>1ρ</sub>) and BE parameters (short T<sub>1ρ</sub>, long T<sub>1ρ</sub>, and short fraction) between AT and HS groups along with repeatability of STFL. The agarose phantom demonstrates biases of 2.89% (3% agarose), -1.88% (5%), and -0.92% (7%) between ME-T<sub>1ρ</sub> values from STFL and CTFL. In the bovine Achilles tendon, STFL shows a large bias of -58.6%, with a lower median ME-T<sub>1ρ</sub> (2.9 ms) than CTFL (4.6 ms). SNR is higher in STFL (77.05-80.72 for 3%-7% agarose; 24.43 for bovine tendon) than CTFL (66.73-58.97 for agarose; 3.21 for bovine tendon). ME and BE parameters were averaged over the entire Achilles tendon, and none showed significant group differences (p > 0.05; effect size = 0.05-0.22). Subregional analysis showed that in the mid-Achilles tendon, short and long BE-T<sub>1ρ</sub> components were 26% and 37% lower in AT than HS, though not statistically significant. The LDA-combined BE parameter showed significant group separation in the midtendon region (p = 0.016; effect size = 1.53). In HS, the long BE-T<sub>1ρ</sub> component showed subregional variation (p = 0.006), increasing 58% from calcaneal to midtendon, and then decreasing 23% toward the intramuscular region. ME and BE fitting showed high repeatability with scan-rescan variations of 2.64% (T<sub>1ρ</sub>), 3.38% (short T<sub>1ρ</sub>), 3.0% (long T<sub>1ρ</sub>), and 0.21% (short fraction). We demonstrated the feasibility of using STFL for T<sub>1ρ</sub> quantification in the Achilles tendon.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-10-09
DOI
https://doi.org/10.1002/nbm.70149
Citations
1
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of a UTE Stack‐of‐Spirals Sequence for T1ρ Mapping of Achilles Tendinopathy

Anmol Monga, Ravinder R. Regatte, Vaibhavi Rathod, Hector Lise de Moura et al.
1 citations
NMR in Biomedicine
Tendon Structure and Treatment
1.72
article

Feasibility of a UTE Stack‐of‐Spirals Sequence for T1ρ Mapping of Achilles Tendinopathy

Anmol Monga, Ravinder R. Regatte, Vaibhavi Rathod, Hector Lise de Moura, Smita Rao, Marcelo V. W. Zibetti
article en
1 citations

Abstract

We analyzed the feasibility of using a UTE stack-of-spirals turbo FLASH (STFL) sequence to measure T<sub>1ρ</sub> relaxation in the Achilles tendon. Six HS (25-31 years) and five AT patients (32-47 years) participated. The study evaluates the clinical utility of the STFL sequence to generate T<sub>1ρ</sub> maps using mono-exponential (ME) and bi-exponential (BE) fitting models. In a phantom experiment, ME-T<sub>1ρ</sub> values and SNR estimated from the STFL sequence are compared with those of the Cartesian turbo FLASH (CTFL) sequence. In human subjects, we evaluate differences in estimated ME (ME-T<sub>1ρ</sub>) and BE parameters (short T<sub>1ρ</sub>, long T<sub>1ρ</sub>, and short fraction) between AT and HS groups along with repeatability of STFL. The agarose phantom demonstrates biases of 2.89% (3% agarose), -1.88% (5%), and -0.92% (7%) between ME-T<sub>1ρ</sub> values from STFL and CTFL. In the bovine Achilles tendon, STFL shows a large bias of -58.6%, with a lower median ME-T<sub>1ρ</sub> (2.9 ms) than CTFL (4.6 ms). SNR is higher in STFL (77.05-80.72 for 3%-7% agarose; 24.43 for bovine tendon) than CTFL (66.73-58.97 for agarose; 3.21 for bovine tendon). ME and BE parameters were averaged over the entire Achilles tendon, and none showed significant group differences (p > 0.05; effect size = 0.05-0.22). Subregional analysis showed that in the mid-Achilles tendon, short and long BE-T<sub>1ρ</sub> components were 26% and 37% lower in AT than HS, though not statistically significant. The LDA-combined BE parameter showed significant group separation in the midtendon region (p = 0.016; effect size = 1.53). In HS, the long BE-T<sub>1ρ</sub> component showed subregional variation (p = 0.006), increasing 58% from calcaneal to midtendon, and then decreasing 23% toward the intramuscular region. ME and BE fitting showed high repeatability with scan-rescan variations of 2.64% (T<sub>1ρ</sub>), 3.38% (short T<sub>1ρ</sub>), 3.0% (long T<sub>1ρ</sub>), and 0.21% (short fraction). We demonstrated the feasibility of using STFL for T<sub>1ρ</sub> quantification in the Achilles tendon.

NMR in BiomedicineVol. 38(11)
New York University (US), Virginia Tech (US)
National Institutes of Health, NYU Grossman School of Medicine, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 14%
Tendon Structure and Treatment
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.