Multicenter performance evaluation of the “quanty TOXO (RH region)” kit (Clonit) for molecular diagnosis of toxoplasmosis

The diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis in immunocompromised patients nowadays relies on molecular tools, in particular real-time PCR. There are many reagents on the market, and their evaluation by independent experts provides valuable information to medical biologists who are looking for a high-performance kit among the different references. Under the aegis of the French National Reference Center for Toxoplasmosis, we report here a multicenter evaluation of the analytical and clinical performances of the "quanty TOXO (RH region)" PCR assay manufactured by Clonit. The kit showed good analytical performance, as indicated by the results of serial dilution tests and external quality control samples. PCR efficiencies varied from 95% to 105%; linearity zone extended over four log units (<i>R</i>² >0.99), and limit of detection varied from <1 parasite/mL to between 1 and 5 parasites/mL, i.e., from <0.08 parasite/PCR to between 0.2 and 1 parasite/PCR, depending on the center. Based on 141 cryopreserved DNAs from a large range of clinical specimens, we determined a clinical sensitivity of 94.7% (71/75; 95% confidence interval [CI]: 87.1%-97.9%) and a clinical specificity of 100% (66/66; 95% CI: 94.5%-100%). Four false negative results were detected despite amplification carried out in duplicate. Overall, the "quanty TOXO (RH region)" PCR assay demonstrated satisfactory analytical and clinical performances for the diagnosis of toxoplasmosis, even using extraction and amplification techniques or biological matrices not validated by the manufacturer.IMPORTANCEDue to its speed and accuracy, PCR is now the gold standard for diagnosing congenital and disseminated toxoplasmosis. High-performance molecular testing is essential, especially for immunocompromised patients and congenital infections, to initiate early treatment. This diagnostic approach increasingly relies on commercial assays. However, commercially available kits do not guarantee performance. In this study, conducted by the French National Reference Center for Toxoplasmosis, we performed an independent multicenter evaluation of the "quanty TOXO (RH region)" PCR assay manufactured by Clonit. Our results showed that this kit delivered satisfactory results for routine diagnostic use. However, among the 141 clinical samples tested, four false negative results were noted, corresponding to specimens with low parasitic load.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Microbiology
Published
2025-10-09
DOI
https://doi.org/10.1128/jcm.00538-25
Citations
1
Primary Topic
Toxoplasma gondii Research Studies
Type
article
Field-Weighted Citation Impact
2.05
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter performance evaluation of the “quanty TOXO (RH region)” kit (Clonit) for molecular diagnosis of toxoplasmosis

Hélène Guegan, Jean Ménotti, Hervé Pelloux, Marie‐Pierre Brenier‐Pinchart et al.
1 citations
Journal of Clinical Microbiology
Toxoplasma gondii Research Studies
2.05
article

Multicenter performance evaluation of the “quanty TOXO (RH region)” kit (Clonit) for molecular diagnosis of toxoplasmosis

Hélène Guegan, Jean Ménotti, Hervé Pelloux, Marie‐Pierre Brenier‐Pinchart, Cécile Nabet, Yvon Sterkers, J. Guitard, Céline Nourrisson, Émilie Varlet
article en
1 citations

Abstract

The diagnosis of congenital toxoplasmosis or disseminated toxoplasmosis in immunocompromised patients nowadays relies on molecular tools, in particular real-time PCR. There are many reagents on the market, and their evaluation by independent experts provides valuable information to medical biologists who are looking for a high-performance kit among the different references. Under the aegis of the French National Reference Center for Toxoplasmosis, we report here a multicenter evaluation of the analytical and clinical performances of the "quanty TOXO (RH region)" PCR assay manufactured by Clonit. The kit showed good analytical performance, as indicated by the results of serial dilution tests and external quality control samples. PCR efficiencies varied from 95% to 105%; linearity zone extended over four log units (<i>R</i>² >0.99), and limit of detection varied from <1 parasite/mL to between 1 and 5 parasites/mL, i.e., from <0.08 parasite/PCR to between 0.2 and 1 parasite/PCR, depending on the center. Based on 141 cryopreserved DNAs from a large range of clinical specimens, we determined a clinical sensitivity of 94.7% (71/75; 95% confidence interval [CI]: 87.1%-97.9%) and a clinical specificity of 100% (66/66; 95% CI: 94.5%-100%). Four false negative results were detected despite amplification carried out in duplicate. Overall, the "quanty TOXO (RH region)" PCR assay demonstrated satisfactory analytical and clinical performances for the diagnosis of toxoplasmosis, even using extraction and amplification techniques or biological matrices not validated by the manufacturer.IMPORTANCEDue to its speed and accuracy, PCR is now the gold standard for diagnosing congenital and disseminated toxoplasmosis. High-performance molecular testing is essential, especially for immunocompromised patients and congenital infections, to initiate early treatment. This diagnostic approach increasingly relies on commercial assays. However, commercially available kits do not guarantee performance. In this study, conducted by the French National Reference Center for Toxoplasmosis, we performed an independent multicenter evaluation of the "quanty TOXO (RH region)" PCR assay manufactured by Clonit. Our results showed that this kit delivered satisfactory results for routine diagnostic use. However, among the 141 clinical samples tested, four false negative results were noted, corresponding to specimens with low parasitic load.

Journal of Clinical MicrobiologyVol. 63(11)
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Lyon College (US), Université de Montpellier (FR), Sorbonne Université (FR), Maladies Infectieuses et Vecteurs: Écologie, Génétique, Évolution et Contrôle (FR), Centre Hospitalier Universitaire de Montpellier (FR), Assistance Publique – Hôpitaux de Paris (FR), Hôpital Saint-Antoine (FR), University of Clermont Auvergne (FR), Laboratoire National de Référence (MA), Pitié-Salpêtrière Hospital (FR), Centre Hospitalier Universitaire de Clermont-Ferrand (FR), Institut Pierre Louis d‘Épidémiologie et de Santé Publique (FR), Centre de Recherche Saint-Antoine (FR), Institute of Parasitology (CZ), Institut de Recherche pour le Développement (FR), Université de Rennes (FR), Université Grenoble Alpes (FR)
Openalex Percentile: Top 12%
Toxoplasma gondii Research Studies
2.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.