Finite element analysis of implant selection and screw positioning in proximal femoral basicervical fractures

To determine the optimal implant for proximal femoral basicervical fractures by comparing the biomechanical properties of the Dynamic Hip Screw (DHS), Proximal Femoral Nail Anti-Rotation (PFNA), and InterTAN using finite element analysis (FEA). Five fixation configurations were simulated: DHS (central screw AP view), PFNA with central helical blade (PFNA-C), PFNA with inferior helical blade (PFNA-I), InterTAN with central hip screw (InterTAN-C), and InterTAN with inferior hip screw (InterTAN-I). Following construction and validation of an intact femur model, three progressively unstable basicervical fracture patterns (simple, intertrochanteric defect, lateral wall defect) were created and incorporated with the implants. FEA simulated a 700 N load (70 kg patient single-leg stance). Displacement and implant stress distribution were analyzed. Primary comparisons assessed DHS, PFNA-C, and InterTAN-C performance; secondary comparisons evaluated screw position (C vs. I) in cephalomedullary nails (CMN). For simple fractures, DHS, PFNA, and InterTAN exhibited minimal differences in displacement and implant stress. In intertrochanteric and lateral wall defect fractures, significant differences emerged. Displacement was significantly greater with DHS, followed by PFNA, then InterTAN (minimal PFNA-InterTAN difference). Maximum stress was highest with InterTAN, higher with PFNA than DHS, but remained below medical titanium fatigue limits. The inferior screw position demonstrated biomechanical advantages over the central position in CMNs. DHS, PFNA, and InterTAN are suitable for simple basicervical fractures. For fractures with intertrochanteric or lateral wall defects, CMNs (PFNA, InterTAN) provide superior stability over DHS, with InterTAN offering marginally better stability than PFNA. The inferior hip screw position is biomechanically preferable in CMNs.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-09
DOI
https://doi.org/10.1038/s41598-025-19260-8
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis of implant selection and screw positioning in proximal femoral basicervical fractures

Zhixin Zhang, Hailun Gu, Tianhao Yang, Baozhe Liu et al.
Scientific Reports
Hip and Femur Fractures
article

Finite element analysis of implant selection and screw positioning in proximal femoral basicervical fractures

Zhixin Zhang, Hailun Gu, Tianhao Yang, Baozhe Liu, Faez Noraddin
article en

Abstract

To determine the optimal implant for proximal femoral basicervical fractures by comparing the biomechanical properties of the Dynamic Hip Screw (DHS), Proximal Femoral Nail Anti-Rotation (PFNA), and InterTAN using finite element analysis (FEA). Five fixation configurations were simulated: DHS (central screw AP view), PFNA with central helical blade (PFNA-C), PFNA with inferior helical blade (PFNA-I), InterTAN with central hip screw (InterTAN-C), and InterTAN with inferior hip screw (InterTAN-I). Following construction and validation of an intact femur model, three progressively unstable basicervical fracture patterns (simple, intertrochanteric defect, lateral wall defect) were created and incorporated with the implants. FEA simulated a 700 N load (70 kg patient single-leg stance). Displacement and implant stress distribution were analyzed. Primary comparisons assessed DHS, PFNA-C, and InterTAN-C performance; secondary comparisons evaluated screw position (C vs. I) in cephalomedullary nails (CMN). For simple fractures, DHS, PFNA, and InterTAN exhibited minimal differences in displacement and implant stress. In intertrochanteric and lateral wall defect fractures, significant differences emerged. Displacement was significantly greater with DHS, followed by PFNA, then InterTAN (minimal PFNA-InterTAN difference). Maximum stress was highest with InterTAN, higher with PFNA than DHS, but remained below medical titanium fatigue limits. The inferior screw position demonstrated biomechanical advantages over the central position in CMNs. DHS, PFNA, and InterTAN are suitable for simple basicervical fractures. For fractures with intertrochanteric or lateral wall defects, CMNs (PFNA, InterTAN) provide superior stability over DHS, with InterTAN offering marginally better stability than PFNA. The inferior hip screw position is biomechanically preferable in CMNs.

Scientific ReportsVol. 15(1)
Police Department (LT), China Medical University (CN)
Openalex Percentile: Top 55%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.