Automatic Removal of Physiological Artifacts in OPM-MEG: A Framework of Channel Attention Mechanism Based on Magnetic Reference Signal

The high spatiotemporal resolution of optically pumped magnetometers (OPMs) makes them an essential tool for functional brain imaging, enabling accurate recordings of neuronal activity. However, physiological signals such as eye blinks and cardiac activity overlap with neural magnetic signals in the frequency domain, resulting in contamination and creating challenges for the observation of brain activity and the study of neurological disorders. To address this problem, an automatic physiological artifact removal method based on OPM magnetic reference signals and a channel attention mechanism is proposed. The randomized dependence coefficient (RDC) is employed to evaluate the correlation between independent components and reference signals, enabling reliable recognition of artifact components and the construction of training and testing datasets. A channel attention mechanism is subsequently introduced, which fuses features from global average pooling (GAP) and global max pooling (GMP) layers through convolution to establish a data-driven automatic recognition model. The backbone network is further optimized to enhance performance. Experimental results demonstrate a strong correlation between the magnetic reference signals and artifact components, confirming the reliability of magnetic signals as artifact references for OPM-MEG. The proposed model achieves an artifact recognition accuracy of 98.52% and a macro-average score of 98.15%. After artifact removal, both the event-related field (ERF) responses and the signal-to-noise ratio (SNR) are significantly improved. Leveraging the flexible and modular characteristics of OPM-MEG, this study introduces an artifact recognition framework that integrates magnetic reference signals with an attention mechanism. This approach enables highly accurate automatic recognition and removal of OPM-MEG artifacts, paving the way for real-time, automated data analysis in both scientific research and clinical applications.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-10-09
DOI
https://doi.org/10.3390/bios15100680
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic Removal of Physiological Artifacts in OPM-MEG: A Framework of Channel Attention Mechanism Based on Magnetic Reference Signal

Xiaolin Ning, Fuzhi Cao, Jianzhi Yang, Yuyu Ma et al.
Biosensors
EEG and Brain-Computer Interfaces
article

Automatic Removal of Physiological Artifacts in OPM-MEG: A Framework of Channel Attention Mechanism Based on Magnetic Reference Signal

Xiaolin Ning, Fuzhi Cao, Jianzhi Yang, Yuyu Ma, Chunhui Wang, Dawei Wang, Hao Lu, Yong Li, Binyi Su
article en

Abstract

The high spatiotemporal resolution of optically pumped magnetometers (OPMs) makes them an essential tool for functional brain imaging, enabling accurate recordings of neuronal activity. However, physiological signals such as eye blinks and cardiac activity overlap with neural magnetic signals in the frequency domain, resulting in contamination and creating challenges for the observation of brain activity and the study of neurological disorders. To address this problem, an automatic physiological artifact removal method based on OPM magnetic reference signals and a channel attention mechanism is proposed. The randomized dependence coefficient (RDC) is employed to evaluate the correlation between independent components and reference signals, enabling reliable recognition of artifact components and the construction of training and testing datasets. A channel attention mechanism is subsequently introduced, which fuses features from global average pooling (GAP) and global max pooling (GMP) layers through convolution to establish a data-driven automatic recognition model. The backbone network is further optimized to enhance performance. Experimental results demonstrate a strong correlation between the magnetic reference signals and artifact components, confirming the reliability of magnetic signals as artifact references for OPM-MEG. The proposed model achieves an artifact recognition accuracy of 98.52% and a macro-average score of 98.15%. After artifact removal, both the event-related field (ERF) responses and the signal-to-noise ratio (SNR) are significantly improved. Leveraging the flexible and modular characteristics of OPM-MEG, this study introduces an artifact recognition framework that integrates magnetic reference signals with an attention mechanism. This approach enables highly accurate automatic recognition and removal of OPM-MEG artifacts, paving the way for real-time, automated data analysis in both scientific research and clinical applications.

BiosensorsVol. 15(10)
Shandong University (CN), Hebei University of Technology (CN), Hefei University (CN), Beijing Microelectronics Technology Institute (CN), Extreme Light Infrastructure - Nuclear Physics (RO), Beihang University (CN)
Openalex Percentile: Top 72%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.