Corrosion Failure Analysis of Heat Exchanger E2111 in the Sour Water Stripping System of the Coal Chemical Industry

ABSTRACT The corrosion failure of heat exchanger E2111 in sour water vaporization system of coal chemical plant was studied. The Aspen Plus software was used to analyze and calculate the corrosive gas composition and equilibrium distribution law of ammonia vapor stripping tower. The results show that the main corrosive gas are CO 2 , NH 3 , H 2 S, and H 2 O in the temperature range of 135.1°C–108.6°C in the E2111. The dew‐point temperature of the water is 134.4°C, meaning that the H 2 O(g) changes into H 2 O(l). With the temperature decreasing, the volume fraction of H 2 O(l) increases, and the corrosive gases are dissolved in the water causing scouring corrosion of the pipe wall. In the E2111, H 2 S and NH 3 partial pressure values can not form the common NH 4 HS salt, which causes a large number of pipeline failures. But the process generated NH 2 COONH 4 salt, which is regarded as the main source of corrosive medium in this case. After corrosion characterization test, it was found that the composition of the residual corrosion products was consistent with calculation results, and the corrosion prior occurred on the outer wall of the tube, that is, shell side.

Authors

Institutions

Publication Details

Journal
Materials and Corrosion
Published
2025-10-07
DOI
https://doi.org/10.1002/maco.70054
Primary Topic
Erosion and Abrasive Machining
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion Failure Analysis of Heat Exchanger E2111 in the Sour Water Stripping System of the Coal Chemical Industry

Li Sun, HeQiao Zhang, Guofu Ou, Zhe Xu et al.
Materials and Corrosion
Erosion and Abrasive Machining
article

Corrosion Failure Analysis of Heat Exchanger E2111 in the Sour Water Stripping System of the Coal Chemical Industry

Li Sun, HeQiao Zhang, Guofu Ou, Zhe Xu, Dexiao Fu
article en

Abstract

ABSTRACT The corrosion failure of heat exchanger E2111 in sour water vaporization system of coal chemical plant was studied. The Aspen Plus software was used to analyze and calculate the corrosive gas composition and equilibrium distribution law of ammonia vapor stripping tower. The results show that the main corrosive gas are CO 2 , NH 3 , H 2 S, and H 2 O in the temperature range of 135.1°C–108.6°C in the E2111. The dew‐point temperature of the water is 134.4°C, meaning that the H 2 O(g) changes into H 2 O(l). With the temperature decreasing, the volume fraction of H 2 O(l) increases, and the corrosive gases are dissolved in the water causing scouring corrosion of the pipe wall. In the E2111, H 2 S and NH 3 partial pressure values can not form the common NH 4 HS salt, which causes a large number of pipeline failures. But the process generated NH 2 COONH 4 salt, which is regarded as the main source of corrosive medium in this case. After corrosion characterization test, it was found that the composition of the residual corrosion products was consistent with calculation results, and the corrosion prior occurred on the outer wall of the tube, that is, shell side.

Materials and CorrosionVol. 77(2)
Northwestern Polytechnical University (CN), Huainan Union University (CN), Yangtze River Delta Physics Research Center (China) (CN), City University of Hong Kong, Shenzhen Research Institute (CN), Changzhou University (CN), Huainan Mining Industry Group (China) (CN)
Openalex Percentile: Top 84%
Erosion and Abrasive Machining
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Corrosion Failure Analysis of Heat Exchanger E2111 in the Sour Water Stripping System of the Coal Chemical Industry — Li Sun, HeQiao Zhang, et al. · Materials and Corrosion (2025) | TGRS Research Map | TGRS