Use of Bayesian decision analysis in the design of patient-centered clinical trials for kidney failure devices

Integrating patient preferences into the design of randomized clinical trials (RCTs) may help accelerate innovation for alternative kidney replacement therapy by appropriately selecting a trial's significance level and sample size, and have a meaningful impact on people suffering from kidney failure. While a conventional one-sided significance level threshold of 2.5 % is often used to assess the safety of a proposed device, we show in this study that it is not necessarily consistent with the risk-preferences of patients with dialysis-dependent kidney disease. We apply a Bayesian decision analysis (BDA) framework to results from a patient preference survey and estimate the optimal significance level and sample size required in an RCT to assess the safety of a hypothetical dialysis device. Based on survey responses from 599 patients with dialysis-dependent kidney failure, we found that the optimal significance level threshold differs significantly from the classical 2.5 % threshold used in two-sided hypothesis tests across various patient subgroups. On average, patients tended to require a significance level of 1.2 % for the risk of bleeding and a significance level <0.1 % for the risk of serious infection, suggesting that the survey respondents were not willing to bear either type of additional risk presented by the hypothetical device in exchange for the possible benefits described in the survey. However, there was heterogeneity among the patient subgroups of dialysis modality, age, gender, ethnicity, and time on dialysis. Overall, our study shows that the BDA framework is a robust, systematic, transparent, and reproducible method for incorporating patient preference information into the design and regulatory review process of clinical trials for novel therapeutics.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-10-09
DOI
https://doi.org/10.1016/j.compbiomed.2025.111150
Primary Topic
Health Systems, Economic Evaluations, Quality of Life
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Bayesian decision analysis in the design of patient-centered clinical trials for kidney failure devices

Katherine Treiman, Dallas Wood, Anindita Saha, Shomesh E. Chaudhuri et al.
Computers in Biology and Medicine
Health Systems, Economic Evaluations, Quality of Life
article

Use of Bayesian decision analysis in the design of patient-centered clinical trials for kidney failure devices

Katherine Treiman, Dallas Wood, Anindita Saha, Shomesh E. Chaudhuri, Michelle E. Tarver, Kien Wei Siah, Raymond Clement Harris, Murray Sheldon, David Gebben, Jennifer E. Flythe, Zied Ben Chaouch, Frank P. Hurst, Carol Mansfield, Melissa West, Qingyang Xu, Andrew W. Lo
article en

Abstract

Integrating patient preferences into the design of randomized clinical trials (RCTs) may help accelerate innovation for alternative kidney replacement therapy by appropriately selecting a trial's significance level and sample size, and have a meaningful impact on people suffering from kidney failure. While a conventional one-sided significance level threshold of 2.5 % is often used to assess the safety of a proposed device, we show in this study that it is not necessarily consistent with the risk-preferences of patients with dialysis-dependent kidney disease. We apply a Bayesian decision analysis (BDA) framework to results from a patient preference survey and estimate the optimal significance level and sample size required in an RCT to assess the safety of a hypothetical dialysis device. Based on survey responses from 599 patients with dialysis-dependent kidney failure, we found that the optimal significance level threshold differs significantly from the classical 2.5 % threshold used in two-sided hypothesis tests across various patient subgroups. On average, patients tended to require a significance level of 1.2 % for the risk of bleeding and a significance level <0.1 % for the risk of serious infection, suggesting that the survey respondents were not willing to bear either type of additional risk presented by the hypothetical device in exchange for the possible benefits described in the survey. However, there was heterogeneity among the patient subgroups of dialysis modality, age, gender, ethnicity, and time on dialysis. Overall, our study shows that the BDA framework is a robust, systematic, transparent, and reproducible method for incorporating patient preference information into the design and regulatory review process of clinical trials for novel therapeutics.

Computers in Biology and MedicineVol. 198(Pt A)
United States Food and Drug Administration (US), Center for Devices and Radiological Health (US), RTI International (US), American Society of Nephrology (US), IIT@MIT (US), Healthcentric Advisors (US), RTI Health Solutions (US), Vanderbilt University Medical Center (US)
Openalex Percentile: Top 63%
Health Systems, Economic Evaluations, Quality of Life
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.