Optimizing colonoscopy‐based colorectal cancer screening by low‐barrier, low‐threshold pretesting

'Gateopener' colonoscopy-based screening is an innovative concept to better target colonoscopy to those who are most likely to benefit from it. It combines invitations to screening colonoscopy with the offer of pretesting with a single 'gateopener' fecal immunochemical test (FIT) which is applied with a lower positivity threshold than in conventional FIT-based screening. We explored optimized use of this approach for reducing CRC incidence and mortality. Using COSIMO, a previously validated simulation tool, we compared outcomes of gateopener screening to those of conventional FIT- or colonoscopy-based screening strategies. Gateopener screening was modelled using SENTiFIT-FOB Gold as exemplary 'gateopener' FIT at various low hemoglobin cut-offs (10, 8, 6, 4, and 3 μg/g feces). We found that Gateopener screening at cut-offs of 6, 4, or 3 μg/g outperformed conventional screening colonoscopy in terms of CRC incidence reduction, with 16%-25%, 50%-57%, and 66%-72% more prevented cases, respectively, after 10 years. All gateopener scenarios significantly increased prevented deaths, at low cut-offs more than doubling the numbers achieved by conventional screening colonoscopy. Compared to biennial FIT, gateopener screening prevented 7%-163% more cases, with lower cut-offs associated with higher gains, and prevented approximately equal to significantly more (12%-21%) CRC deaths. Cut-offs of 10 and 8 μg/g required fewer colonoscopies per prevented case and death. Gateopener screening outperforms conventional CRC screening by offering considerably stronger reduction of CRC incidence and mortality rates as well as considerably increased screening effectiveness. The feasibility of the concept should be assessed by a pilot study in real-life practice.

Authors

Institutions

Publication Details

Journal
International Journal of Cancer
Published
2025-10-09
DOI
https://doi.org/10.1002/ijc.70187
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing colonoscopy‐based colorectal cancer screening by low‐barrier, low‐threshold pretesting

Rafael Cardoso, Thomas Heisser, Michael Hoffmeister, Tobias Niedermaier et al.
International Journal of Cancer
Colorectal Cancer Screening and Detection
article

Optimizing colonoscopy‐based colorectal cancer screening by low‐barrier, low‐threshold pretesting

Rafael Cardoso, Thomas Heisser, Michael Hoffmeister, Tobias Niedermaier, Hermann Brenner
article en

Abstract

'Gateopener' colonoscopy-based screening is an innovative concept to better target colonoscopy to those who are most likely to benefit from it. It combines invitations to screening colonoscopy with the offer of pretesting with a single 'gateopener' fecal immunochemical test (FIT) which is applied with a lower positivity threshold than in conventional FIT-based screening. We explored optimized use of this approach for reducing CRC incidence and mortality. Using COSIMO, a previously validated simulation tool, we compared outcomes of gateopener screening to those of conventional FIT- or colonoscopy-based screening strategies. Gateopener screening was modelled using SENTiFIT-FOB Gold as exemplary 'gateopener' FIT at various low hemoglobin cut-offs (10, 8, 6, 4, and 3 μg/g feces). We found that Gateopener screening at cut-offs of 6, 4, or 3 μg/g outperformed conventional screening colonoscopy in terms of CRC incidence reduction, with 16%-25%, 50%-57%, and 66%-72% more prevented cases, respectively, after 10 years. All gateopener scenarios significantly increased prevented deaths, at low cut-offs more than doubling the numbers achieved by conventional screening colonoscopy. Compared to biennial FIT, gateopener screening prevented 7%-163% more cases, with lower cut-offs associated with higher gains, and prevented approximately equal to significantly more (12%-21%) CRC deaths. Cut-offs of 10 and 8 μg/g required fewer colonoscopies per prevented case and death. Gateopener screening outperforms conventional CRC screening by offering considerably stronger reduction of CRC incidence and mortality rates as well as considerably increased screening effectiveness. The feasibility of the concept should be assessed by a pilot study in real-life practice.

International Journal of CancerVol. 158(6)
German Cancer Research Center (DE), Heidelberg University (DE)
Bundesministerium für Bildung und Forschung, Deutsche Krebshilfe
Openalex Percentile: Top 61%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.