Optical-Tattoo Sensing for Non-contact Control of Bionic Limbs: A Conceptual Framework

Conventional pattern recognition (PR) methods in bionic hand systems are reliant on contact-based sensors and remain vulnerable to the inherent instability of biological signals. This study presents an alternative method that uses a novel non-contact PR approach to classify the motion of individual fingers and hand grasping gestures. This method does not depend on biosignals; instead, it utilises optical sensing. To enhance optical differentiation during muscle contraction, interference-pigment tattoos were applied to the targeted areas of the skin of the muscular areas. In this approach, muscle activity in the forearm's flexor medialis region is captured through red-green-blue (RGB) colour information and reflected light intensity (LI), which is then processed by a low execution time (ET) and an accurate recognition system. Two integrated sensors were used to precisely detect light reflections associated with a group of muscle activities. To minimise feeding data to the system, the RGB signals were clustered by light intensity using the k-nearest neighbours (KNN) algorithm, and then both time-domain and wavelet features were extracted and classified using four classifiers, including linear discriminant analysis (LDA), support vector machine (SVM), multilayer perceptron (MLP), and convolutional neural network (CNN). In the golden-integrated tattoo design, the system demonstrated a mean accuracy of 97.74%±0.8% across twelve intact participants and a mean accuracy of 95.23%±1.2% across six wrist disarticulation amputees, both classified as athletes and non-athletes. This underscores its strong potential as an alternative method to enhance the accuracy, intuitiveness, and reliability of prosthetic hand control systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-01-01
DOI
https://doi.org/10.1109/tnsre.2025.3618615
Primary Topic
Teleoperation and Haptic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical-Tattoo Sensing for Non-contact Control of Bionic Limbs: A Conceptual Framework

Farzaneh Norouzi, Saeed Bahrami Moqadam, Ahmad Saleh Asheghabadi
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Teleoperation and Haptic Systems
article

Optical-Tattoo Sensing for Non-contact Control of Bionic Limbs: A Conceptual Framework

Farzaneh Norouzi, Saeed Bahrami Moqadam, Ahmad Saleh Asheghabadi
article en

Abstract

Conventional pattern recognition (PR) methods in bionic hand systems are reliant on contact-based sensors and remain vulnerable to the inherent instability of biological signals. This study presents an alternative method that uses a novel non-contact PR approach to classify the motion of individual fingers and hand grasping gestures. This method does not depend on biosignals; instead, it utilises optical sensing. To enhance optical differentiation during muscle contraction, interference-pigment tattoos were applied to the targeted areas of the skin of the muscular areas. In this approach, muscle activity in the forearm's flexor medialis region is captured through red-green-blue (RGB) colour information and reflected light intensity (LI), which is then processed by a low execution time (ET) and an accurate recognition system. Two integrated sensors were used to precisely detect light reflections associated with a group of muscle activities. To minimise feeding data to the system, the RGB signals were clustered by light intensity using the k-nearest neighbours (KNN) algorithm, and then both time-domain and wavelet features were extracted and classified using four classifiers, including linear discriminant analysis (LDA), support vector machine (SVM), multilayer perceptron (MLP), and convolutional neural network (CNN). In the golden-integrated tattoo design, the system demonstrated a mean accuracy of 97.74%±0.8% across twelve intact participants and a mean accuracy of 95.23%±1.2% across six wrist disarticulation amputees, both classified as athletes and non-athletes. This underscores its strong potential as an alternative method to enhance the accuracy, intuitiveness, and reliability of prosthetic hand control systems.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 33
Tongji University (CN), Shanghai Jiao Tong University (CN), Renji Hospital (CN), Tsinghua University (CN)
Openalex Percentile: Top 71%
Teleoperation and Haptic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optical-Tattoo Sensing for Non-contact Control of Bionic Limbs: A Conceptual Framework — Farzaneh Norouzi, Saeed Bahrami Moqadam, et al. · IEEE Transactions on Neural Systems and Rehabilitation Engineering (2025) | TGRS Research Map | TGRS