Comparison of the Radiopacity of Zinc Oxide-eugenol Cements using Different Radiographic Methods

Aims: To evaluate whether there is a difference in the radiopacity of four endodontic sealers, using two imaging techniques. Study Design: Experimental study, with a quantitative approach. Place and Duration of Study: Research Laboratory - Dentistry Course at the University of Fortaleza (UNIFOR), between June 2024 and May 2025. Methodology: Four endodontic sealers (Endofill, Ciment-Fill, Pulp Fill, and Fill Canal) were prepared according to the manufacturer's instructions and inserted into 10 mm diameter x 1 mm high rings, with three samples per group (n = 3), totaling n = 12. After complete setting, the samples were positioned on radiographic occlusal films, next to an aluminum penetrometer and exposed to X-rays (60 kV, 10 mA, 0.3 s, at 30 cm), using a digital sensor and analog method. Radiopacity was analyzed in the Photopea program, converting the radiographic density into millimeters of aluminum. Results: Digital radiography showed greater sensitivity in detecting radiopacity, with a statistically significant difference compared to the analog technique (P < 0.05). Endofill showed the highest radiopacity in both methods, significantly surpassing Pulp Fill and Fill Canal. Ciment-Fill presented intermediate values, similar to Pulp Fill, with no statistical difference between them (P > 0.05). Fill Canal presented the lowest radiopacity, significantly lower than the others (P < 0.05), which may compromise its clinical visibility. Conclusion: The materials tested are within the values ​​proposed by the American Dental Association (2000), specification no. 57 and no. 6876 of the International Organization for Standardization (ISO). In addition to evaluating the radiopacity density, the digital radiographic technique presented superior results to the analog, both revealing positive results.

Authors

Institutions

Publication Details

Journal
Archives of Current Research International
Published
2025-10-09
DOI
https://doi.org/10.9734/acri/2025/v25i101551
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Radiopacity of Zinc Oxide-eugenol Cements using Different Radiographic Methods

Luiz Carlos Trévia Morais Correia Viana, Aldo Angelim Dias, Alinne Patierry Oliveira Pacífico Feitosa, Yana Cavalcante De Araújo et al.
Archives of Current Research International
Dental Radiography and Imaging
article

Comparison of the Radiopacity of Zinc Oxide-eugenol Cements using Different Radiographic Methods

Luiz Carlos Trévia Morais Correia Viana, Aldo Angelim Dias, Alinne Patierry Oliveira Pacífico Feitosa, Yana Cavalcante De Araújo, Fábio de Almeida Gomes, Bernardo Almeida Aguiar, Bruno Carvalho de Vasconcelos, Eduardo Diogo Gurgel Filho, Lucas Kallas-Silva, Teresa Branco, Kamila Nascimento de Sousa
article en

Abstract

Aims: To evaluate whether there is a difference in the radiopacity of four endodontic sealers, using two imaging techniques. Study Design: Experimental study, with a quantitative approach. Place and Duration of Study: Research Laboratory - Dentistry Course at the University of Fortaleza (UNIFOR), between June 2024 and May 2025. Methodology: Four endodontic sealers (Endofill, Ciment-Fill, Pulp Fill, and Fill Canal) were prepared according to the manufacturer's instructions and inserted into 10 mm diameter x 1 mm high rings, with three samples per group (n = 3), totaling n = 12. After complete setting, the samples were positioned on radiographic occlusal films, next to an aluminum penetrometer and exposed to X-rays (60 kV, 10 mA, 0.3 s, at 30 cm), using a digital sensor and analog method. Radiopacity was analyzed in the Photopea program, converting the radiographic density into millimeters of aluminum. Results: Digital radiography showed greater sensitivity in detecting radiopacity, with a statistically significant difference compared to the analog technique (P < 0.05). Endofill showed the highest radiopacity in both methods, significantly surpassing Pulp Fill and Fill Canal. Ciment-Fill presented intermediate values, similar to Pulp Fill, with no statistical difference between them (P > 0.05). Fill Canal presented the lowest radiopacity, significantly lower than the others (P < 0.05), which may compromise its clinical visibility. Conclusion: The materials tested are within the values ​​proposed by the American Dental Association (2000), specification no. 57 and no. 6876 of the International Organization for Standardization (ISO). In addition to evaluating the radiopacity density, the digital radiographic technique presented superior results to the analog, both revealing positive results.

Archives of Current Research InternationalVol. 25(10)
Universidade Federal do Ceará (BR), Universidade de Fortaleza (BR), Hospital de Messejana (BR)
Openalex Percentile: Top 61%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.