High-precision and fast-response Graphene-Au interdigitated electrode for long-term stability in wearable EEG and ECG monitoring

Developing highly sensitive and stable biomedical electrodes is crucial for brain-computer interfaces, wearable devices, and implantable devices. Research on biomedical electrode materials has made certain progress; however, there is still a need for further improvement in providing sufficient spatial and temporal resolution to monitor more regions, as well as in providing reliable and stable long-term recording. Herein, Graphene-Au interdigitated electrodes have been developed for high-fidelity, simultaneous acquisition of electrocardiography (ECG) and electroencephalography (EEG) signals. In this work, the graphene material exhibits excellent electrical conductivity and good biocompatibility, and the interdigitated electrode structure can improve the collection accuracy and response time. The results show a rapid response time of 412 ns and a low electrode-electrolyte interface impedance of 20.8 Ω for lateral conduction on dry skin, alongside a contact impedance of 207 k Ω at 200 Pa, demonstrating high sensitivity and signal integrity. The electrodes exhibit stable and consistent performance in acquiring EEG and ECG signals, with accuracy comparable to traditional Ag/AgCl electrodes, as validated in emotion monitoring experiments capturing distinct physiological features. Additionally, the electrodes demonstrate exceptional durability for continuous health monitoring, maintaining a stable root mean square (RMS) peak signal of 201 ± 16 μ V and a 100% P-wave detection rate in ECG recordings throughout 700 bending cycles. It overcomes traditional electrodes’ limitations in temporal resolution, biocompatibility, and long-term stability. This work provides a novel approach for designing next-generation flexible wearable medical monitoring devices.

Authors

Institutions

Publication Details

Journal
Journal of Science Advanced Materials and Devices
Published
2025-10-09
DOI
https://doi.org/10.1016/j.jsamd.2025.101016
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-precision and fast-response Graphene-Au interdigitated electrode for long-term stability in wearable EEG and ECG monitoring

Xiuling Liu, Changyong Wang, Jieshuo Zhang, Licong Li et al.
Journal of Science Advanced Materials and Devices
Advanced Sensor and Energy Harvesting Materials
article

High-precision and fast-response Graphene-Au interdigitated electrode for long-term stability in wearable EEG and ECG monitoring

Xiuling Liu, Changyong Wang, Jieshuo Zhang, Licong Li, Peng Xiong, Y. He, Yanping Zheng, Jianli Yang, Yifan Li, Jiaming Zhang, Yixing Zhang, Yang He, Jiamin Hu
article en

Abstract

Developing highly sensitive and stable biomedical electrodes is crucial for brain-computer interfaces, wearable devices, and implantable devices. Research on biomedical electrode materials has made certain progress; however, there is still a need for further improvement in providing sufficient spatial and temporal resolution to monitor more regions, as well as in providing reliable and stable long-term recording. Herein, Graphene-Au interdigitated electrodes have been developed for high-fidelity, simultaneous acquisition of electrocardiography (ECG) and electroencephalography (EEG) signals. In this work, the graphene material exhibits excellent electrical conductivity and good biocompatibility, and the interdigitated electrode structure can improve the collection accuracy and response time. The results show a rapid response time of 412 ns and a low electrode-electrolyte interface impedance of 20.8 Ω for lateral conduction on dry skin, alongside a contact impedance of 207 k Ω at 200 Pa, demonstrating high sensitivity and signal integrity. The electrodes exhibit stable and consistent performance in acquiring EEG and ECG signals, with accuracy comparable to traditional Ag/AgCl electrodes, as validated in emotion monitoring experiments capturing distinct physiological features. Additionally, the electrodes demonstrate exceptional durability for continuous health monitoring, maintaining a stable root mean square (RMS) peak signal of 201 ± 16 μ V and a 100% P-wave detection rate in ECG recordings throughout 700 bending cycles. It overcomes traditional electrodes’ limitations in temporal resolution, biocompatibility, and long-term stability. This work provides a novel approach for designing next-generation flexible wearable medical monitoring devices.

Journal of Science Advanced Materials and DevicesVol. 10(4)
Academy of Military Medical Sciences (CN), Hebei University (CN)
Openalex Percentile: Top 73%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.