Cooling of a hot elastic wall in a double vented cavity system by using sinusoidal corrugated porous partition during hybrid nanofluid forced convection and AI-assisted modeling

The need for new cooling solutions is growing for thermal management and energy storage in various energy systems. This study proposes a novel cooling system for sinusoidal corrugated porous partition (SCPP) with hybrid nanofluid for hot elastic wall in a double vented cavity (VEC) system. Both rigid and elastic wall scenarios are taken into consideration in the numerical analysis based on the finite element method (FEM), which is carried out for various values of the left cavity flow Reynolds number ( Re L between 200 and 1000), wave amplitude ( A f between 0.01 and 0.25), and wave number ( N f between 1 and 6) of SCPP. A cooling model is developed using an artificial neural network (ANN) approach, and comparisons with computational fluid dynamics (CFD) simulations are executed. In contrast to the rigid scenario, the vortex size below the entrance port is impacted at the maximum Re L due to the heated elastic wall’s significant deformation. In the case of rigid walls, the average Nusselt number (Nu) with Re L is enhanced by 132%, whereas in the case of elastic walls, it is enhanced by 255%. The cooling performance improvement with the highest corrugation amplitude is 7.2% for rigid case and 12.4% for elastic case. The average Nu variation increases by 3% for elastic scenarios and by 9% for rigid scenarios when the wave number of corrugation is changed. The optimal cooling performance is achieved with the ANN model for rigid walled configuration at ( Re L , A f , N f )=(1000, 0.25, 3), and for elastic walled configuration at ( Re L , A f , N f )=(1000, 0.25, 2). The maximum cooling performance case provides cooling performance boost factors of 4.16 and 4.32 for the rigid and elastic cases, respectively, in contrast to the reference configuration of Re L =200 with a flat partition.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-10-09
DOI
https://doi.org/10.1016/j.csite.2025.107188
Citations
3
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cooling of a hot elastic wall in a double vented cavity system by using sinusoidal corrugated porous partition during hybrid nanofluid forced convection and AI-assisted modeling

Fatih Selımefendıgıl, Chemseddine Maatki, Lioua Kolsi
3 citations
Case Studies in Thermal Engineering
Nanofluid Flow and Heat Transfer
2.02
article

Cooling of a hot elastic wall in a double vented cavity system by using sinusoidal corrugated porous partition during hybrid nanofluid forced convection and AI-assisted modeling

Fatih Selımefendıgıl, Chemseddine Maatki, Lioua Kolsi
article en
3 citations

Abstract

The need for new cooling solutions is growing for thermal management and energy storage in various energy systems. This study proposes a novel cooling system for sinusoidal corrugated porous partition (SCPP) with hybrid nanofluid for hot elastic wall in a double vented cavity (VEC) system. Both rigid and elastic wall scenarios are taken into consideration in the numerical analysis based on the finite element method (FEM), which is carried out for various values of the left cavity flow Reynolds number ( Re L between 200 and 1000), wave amplitude ( A f between 0.01 and 0.25), and wave number ( N f between 1 and 6) of SCPP. A cooling model is developed using an artificial neural network (ANN) approach, and comparisons with computational fluid dynamics (CFD) simulations are executed. In contrast to the rigid scenario, the vortex size below the entrance port is impacted at the maximum Re L due to the heated elastic wall’s significant deformation. In the case of rigid walls, the average Nusselt number (Nu) with Re L is enhanced by 132%, whereas in the case of elastic walls, it is enhanced by 255%. The cooling performance improvement with the highest corrugation amplitude is 7.2% for rigid case and 12.4% for elastic case. The average Nu variation increases by 3% for elastic scenarios and by 9% for rigid scenarios when the wave number of corrugation is changed. The optimal cooling performance is achieved with the ANN model for rigid walled configuration at ( Re L , A f , N f )=(1000, 0.25, 3), and for elastic walled configuration at ( Re L , A f , N f )=(1000, 0.25, 2). The maximum cooling performance case provides cooling performance boost factors of 4.16 and 4.32 for the rigid and elastic cases, respectively, in contrast to the reference configuration of Re L =200 with a flat partition.

Case Studies in Thermal EngineeringVol. 75
Manisa Celal Bayar University (TR), Imam Mohammad ibn Saud Islamic University (SA), University of Ha'il (SA)
Openalex Percentile: Top 12%
Nanofluid Flow and Heat Transfer
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.