Investigation of the standardization method with scattered x-rays in matrices prepared with different diluters

In this study, it is considered to evaluate the spectral intensity ratios for different matrices to be prepared using MnO2 and boric acid, sugar, starch and cellulose as binders. The areas under the Compton and coherent scattering peaks with Mn K X-ray were calculated and the relationship between different intensity ratios and the mean atomic number of diluted samples was investigated. 100 mCi Am-241point radioactive source was used to excite the targets. The emitted and scattered X-rays from targets were counted by a ULEGe detector. The changes in the scattering intensity ratios of the mean atomic numbers of the matrices prepared using different diluents were plotted graphically, the calibration curves and correlation coefficients obtained were interpreted. In addition, there is a third-degree polynomial relationship between Icoh+IComp/(μ/ρ)(Kα) intensity ratio of the prepared sample group and mean atomic number. The obtained calibration curves can be used for qualitative analysis in sample groups with the same matrix.

Authors

Institutions

Publication Details

Journal
DergiPark (Istanbul University)
Published
2025-06-27
DOI
https://doi.org/10.5281/zenodo.15739317
Primary Topic
Cultural and Sociopolitical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the standardization method with scattered x-rays in matrices prepared with different diluters

Demet Yılmaz, Adem Korkmaz
DergiPark (Istanbul University)
Cultural and Sociopolitical Studies
article

Investigation of the standardization method with scattered x-rays in matrices prepared with different diluters

Demet Yılmaz, Adem Korkmaz
article en

Abstract

In this study, it is considered to evaluate the spectral intensity ratios for different matrices to be prepared using MnO2 and boric acid, sugar, starch and cellulose as binders. The areas under the Compton and coherent scattering peaks with Mn K X-ray were calculated and the relationship between different intensity ratios and the mean atomic number of diluted samples was investigated. 100 mCi Am-241point radioactive source was used to excite the targets. The emitted and scattered X-rays from targets were counted by a ULEGe detector. The changes in the scattering intensity ratios of the mean atomic numbers of the matrices prepared using different diluents were plotted graphically, the calibration curves and correlation coefficients obtained were interpreted. In addition, there is a third-degree polynomial relationship between Icoh+IComp/(μ/ρ)(Kα) intensity ratio of the prepared sample group and mean atomic number. The obtained calibration curves can be used for qualitative analysis in sample groups with the same matrix.

DergiPark (Istanbul University)
Atatürk University (TR)
Openalex Percentile: Top 73%
Cultural and Sociopolitical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of the standardization method with scattered x-rays in matrices prepared with different diluters — Demet Yılmaz, Adem Korkmaz · DergiPark (Istanbul University) (2025) | TGRS Research Map | TGRS