Validation of an Optimized <scp>DuraClone</scp> Phenotyping Kit Workflow for <scp>TBNK</scp> Subset Quantification

Quantification of T-cells, B-cells, and NK-cells assay is crucial for diagnosing and monitoring immune diseases and evaluating lymphodepleting therapies. To standardize and validate an optimized workflow of the Beckman Coulter DuraClone IM Phenotyping Basic Kit for quantification of TBNK subsets in peripheral blood. Procedural changes included the use of an alternative lysis buffer, the addition of counting beads, the elimination of centrifugation steps, and an increase in acquisition volume. Validation followed CLSI H42-A2 and H62 guidelines, assessing accuracy, precision, linearity, and limit of quantification (LLOQ). Accuracy was evaluated by comparison with Immuno-Trol controls and by Bland-Altman analysis against standard immunophenotyping methods. External proficiency was assessed through participation in the College of American Pathologists (CAP) TBNK program in 2024. Procedural steps were reduced by 50%, and processing time by 38.6%. The modified method demonstrated high accuracy (-3 < bias < 35; cells/μL), a low bias based on Immuno-Trol targets, and strong agreement in the Bland-Altman analysis. The method successfully passed three CAP external proficiency tests in 2024, confirming interlaboratory reliability. Coefficients of variation for precision were below 10% for all subsets. Linearity exceeded R <sup>2</sup> > 0.99 across clinically relevant ranges. Most subsets demonstrated an LLOQ below 10-50 cells/μL, which is suitable for clinical applications. The proposed modifications to the DuraClone IM kit protocol improved workflow efficiency and analytical performance without compromising accuracy or reproducibility. The validated method provides a standardized, reliable, and time-efficient alternative for lymphocyte subset quantification.

Authors

Institutions

Publication Details

Journal
Cytometry Part A
Published
2025-10-01
DOI
https://doi.org/10.1002/cyto.a.24967
Primary Topic
CAR-T cell therapy research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an Optimized DuraClone Phenotyping Kit Workflow for TBNK Subset Quantification

Yendry Ventura‐Carmenate, Yaíma Zúñiga Rosales, Imilla Casado Hernández, Carlos Agustín Villegas Valverde et al.
Cytometry Part A
CAR-T cell therapy research
article

Validation of an Optimized DuraClone Phenotyping Kit Workflow for TBNK Subset Quantification

Yendry Ventura‐Carmenate, Yaíma Zúñiga Rosales, Imilla Casado Hernández, Carlos Agustín Villegas Valverde, Antonio Alfonso Bencomo‐Hernandez, Fatma Abdou, Shadi Sharif Shamat
article en

Abstract

Quantification of T-cells, B-cells, and NK-cells assay is crucial for diagnosing and monitoring immune diseases and evaluating lymphodepleting therapies. To standardize and validate an optimized workflow of the Beckman Coulter DuraClone IM Phenotyping Basic Kit for quantification of TBNK subsets in peripheral blood. Procedural changes included the use of an alternative lysis buffer, the addition of counting beads, the elimination of centrifugation steps, and an increase in acquisition volume. Validation followed CLSI H42-A2 and H62 guidelines, assessing accuracy, precision, linearity, and limit of quantification (LLOQ). Accuracy was evaluated by comparison with Immuno-Trol controls and by Bland-Altman analysis against standard immunophenotyping methods. External proficiency was assessed through participation in the College of American Pathologists (CAP) TBNK program in 2024. Procedural steps were reduced by 50%, and processing time by 38.6%. The modified method demonstrated high accuracy (-3 < bias < 35; cells/μL), a low bias based on Immuno-Trol targets, and strong agreement in the Bland-Altman analysis. The method successfully passed three CAP external proficiency tests in 2024, confirming interlaboratory reliability. Coefficients of variation for precision were below 10% for all subsets. Linearity exceeded R <sup>2</sup> > 0.99 across clinically relevant ranges. Most subsets demonstrated an LLOQ below 10-50 cells/μL, which is suitable for clinical applications. The proposed modifications to the DuraClone IM kit protocol improved workflow efficiency and analytical performance without compromising accuracy or reproducibility. The validated method provides a standardized, reliable, and time-efficient alternative for lymphocyte subset quantification.

Cytometry Part AVol. 107(10)
Abu Dhabi University (AE)
Openalex Percentile: Top 61%
CAR-T cell therapy research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.