A popular validated home monitor uses the maximum oscillogram amplitude to compute blood pressure

Oscillometric cuff devices are believed to use fixed ratio algorithms to compute blood pressure (BP) from the oscillogram (cuff pressure oscillation height versus applied cuff pressure function). However, variations in the cuff transducer that occur each time the cuff is wrapped on a given arm and variations in pulse pressure can alter the oscillogram shape and the ratios for computing BP. A popular validated home BP monitor was studied to determine whether and how it considers these effects. The monitor, with its Universal cuff placed on four different mandrels, was analyzed using a non-invasive BP simulator at various settings and an external pressure sensor to construct the oscillograms. Several algorithms were tested to estimate the home monitor BP values. A fixed ratio algorithm estimated the home monitor systolic and diastolic BP with errors of 5.8 and 1.5 mmHg. A variable ratio algorithm in which the ratios go inversely with the maximum oscillogram amplitude estimated the home monitor values with errors of just 1.5 and 0.8 mmHg. Using the maximum oscillogram amplitude may be particularly helpful for mitigating the variable pulse pressure effect. This study shows how oscillometric cuff devices likely work, which is important for understanding and improving their accuracy.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-08
DOI
https://doi.org/10.1038/s41598-025-18850-w
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A popular validated home monitor uses the maximum oscillogram amplitude to compute blood pressure

Vishaal Dhamotharan, Sanjeev G. Shroff, Jin‐Oh Hahn, Hadi Daher et al.
1 citations
Scientific Reports
Non-Invasive Vital Sign Monitoring
0.67
article

A popular validated home monitor uses the maximum oscillogram amplitude to compute blood pressure

Vishaal Dhamotharan, Sanjeev G. Shroff, Jin‐Oh Hahn, Hadi Daher, Ramakrishna Mukkamala, Aman Mahajan, Ravinder Kumar, Mahdi Jazini
article en
1 citations

Abstract

Oscillometric cuff devices are believed to use fixed ratio algorithms to compute blood pressure (BP) from the oscillogram (cuff pressure oscillation height versus applied cuff pressure function). However, variations in the cuff transducer that occur each time the cuff is wrapped on a given arm and variations in pulse pressure can alter the oscillogram shape and the ratios for computing BP. A popular validated home BP monitor was studied to determine whether and how it considers these effects. The monitor, with its Universal cuff placed on four different mandrels, was analyzed using a non-invasive BP simulator at various settings and an external pressure sensor to construct the oscillograms. Several algorithms were tested to estimate the home monitor BP values. A fixed ratio algorithm estimated the home monitor systolic and diastolic BP with errors of 5.8 and 1.5 mmHg. A variable ratio algorithm in which the ratios go inversely with the maximum oscillogram amplitude estimated the home monitor values with errors of just 1.5 and 0.8 mmHg. Using the maximum oscillogram amplitude may be particularly helpful for mitigating the variable pulse pressure effect. This study shows how oscillometric cuff devices likely work, which is important for understanding and improving their accuracy.

Scientific ReportsVol. 15(1)
University of Pittsburgh (US), University of Maryland, College Park (US)
National Institutes of Health, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 26%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.