Performance evaluation of high-resolution DOI-encoded PET detectors with single-ended multiplexed readout circuitry

Abstract This study achieved high-performance depth-of-interaction (DOI) encoding in PET detectors through systematic optimization of crystal surface reflection processing, utilizing a light-sharing redirection mechanism. We employed a 23 × 23 LYSO array coupled to an 8 × 8 SiPM array under a 9:1 crystal-to-photodetector coupling ratio. Three detector designs with different surface treatments were investigated: Detector I (1.02 × 1.02 × 15 mm 3 crystals, fully polished with E60 film), Detector II (1 × 1 × 15 mm 3 crystals, ESR-wrapped with unpolished sidewalls), and Detector III (1 × 1 × 15 mm 3 crystals, fully polished with ESR film). Detector I achieved the best DOI resolution (3.29 mm FWHM), while Detector II reached 4.13 mm, both detectors can achieve good crystal separation after layering, enabling effective discrete identification. Notably, the Detector III design enabled direct crystal discrimination without layered structures but exhibited compromised depth sensing capability. Energy resolution in the central region was 16.22%, 13.72%, and 11.54% for Detectors I–III, respectively, and the corresponding timing resolutions were 1.45 ns, 1.02 ns, and 1.64 ns. Taking all aspects into consideration, Detector II exhibited the most balanced performance, indicating that selective surface texturing (e.g., sidewall unpolishing) combined with high-reflectivity materials (ESR) can effectively optimize photon transport pathways. This methodology enables efficient DOI information capture while maintaining compatibility with existing PET electronics, providing a technically viable solution for next-generation high-resolution PET systems that integrates performance advantages with engineering feasibility.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-10-01
DOI
https://doi.org/10.1088/1748-0221/20/10/p10015
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of high-resolution DOI-encoded PET detectors with single-ended multiplexed readout circuitry

Xiaorou Han, Zexin Zhang, Daowu Li, Peilin Wang et al.
Journal of Instrumentation
Medical Imaging Techniques and Applications
article

Performance evaluation of high-resolution DOI-encoded PET detectors with single-ended multiplexed readout circuitry

Xiaorou Han, Zexin Zhang, Daowu Li, Peilin Wang, Zhiming Zhang, Zhuoran Wang, Long Wei, Meiling Zhu, Yingjie Wang, Xianchao Huang, Hang Yuan
article en

Abstract

Abstract This study achieved high-performance depth-of-interaction (DOI) encoding in PET detectors through systematic optimization of crystal surface reflection processing, utilizing a light-sharing redirection mechanism. We employed a 23 × 23 LYSO array coupled to an 8 × 8 SiPM array under a 9:1 crystal-to-photodetector coupling ratio. Three detector designs with different surface treatments were investigated: Detector I (1.02 × 1.02 × 15 mm 3 crystals, fully polished with E60 film), Detector II (1 × 1 × 15 mm 3 crystals, ESR-wrapped with unpolished sidewalls), and Detector III (1 × 1 × 15 mm 3 crystals, fully polished with ESR film). Detector I achieved the best DOI resolution (3.29 mm FWHM), while Detector II reached 4.13 mm, both detectors can achieve good crystal separation after layering, enabling effective discrete identification. Notably, the Detector III design enabled direct crystal discrimination without layered structures but exhibited compromised depth sensing capability. Energy resolution in the central region was 16.22%, 13.72%, and 11.54% for Detectors I–III, respectively, and the corresponding timing resolutions were 1.45 ns, 1.02 ns, and 1.64 ns. Taking all aspects into consideration, Detector II exhibited the most balanced performance, indicating that selective surface texturing (e.g., sidewall unpolishing) combined with high-reflectivity materials (ESR) can effectively optimize photon transport pathways. This methodology enables efficient DOI information capture while maintaining compatibility with existing PET electronics, providing a technically viable solution for next-generation high-resolution PET systems that integrates performance advantages with engineering feasibility.

Journal of InstrumentationVol. 20(10)
University of Jinan (CN), Technology Applications (United States) (US), Institute of High Energy Physics (AT), Key Laboratory of Nuclear Radiation and Nuclear Energy Technology (CN), Institute of High Energy Physics (CN), Jinan University (LB), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 58%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.