Current trends in near ambient pressure x-ray photoelectron spectroscopy (NAP-XPS). Degree of reporting of instrument parameters

A thorough understanding of x-ray photoelectron spectroscopy (XPS) results requires well-reported data collection and analysis parameters. Near ambient pressure (NAP)-XPS instrument parameters are not always reported as thoroughly as they could be in the scientific literature. This paper examines parameter reporting within the main bodies of NAP-XPS papers published from 2021 to 2023. Parameters studied include the analyzer, photon flux, x-ray source and energy, spot size, pass energy, signal integration parameters, incident angle, substrate temperature, aperture size and distance, background gas, and fitting parameters such as the background and synthetic peak shapes. On average, less than 50% of these instrument parameters are reported within the main bodies of papers, although some parameters are reported better than others. For instance, the analysis chamber pressure is reported 94% of the time, while signal integration parameters are only reported 6% of the time. Over 50% of NAP-XPS experiments are conducted at synchrotrons. Most NAP-XPS papers (92%) contain fitted data, but fewer than 50% of these papers reported peak fitting parameters. Fewer than 5% of NAP-XPS studies are operando. While this study reveals some shortcomings in reporting, because not all NAP-XPS instrument parameters are of equal importance in all experiments, and because parameter reporting also took place in the supporting information of some papers, papers that did not report all possible parameters in their main bodies do not necessarily constitute irreproducible work. Some of the experimental details and data related to a study in the supporting information sections of papers should often be included within the papers themselves, perhaps as appendices.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Published
2025-10-08
DOI
https://doi.org/10.1116/6.0004754
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current trends in near ambient pressure x-ray photoelectron spectroscopy (NAP-XPS). Degree of reporting of instrument parameters

Joshua W. Pinder, Andreas Thißen, Matthew R. Linford, Paul Dietrich et al.
Journal of Vacuum Science & Technology A Vacuum Surfaces and Films
Electron and X-Ray Spectroscopy Techniques
article

Current trends in near ambient pressure x-ray photoelectron spectroscopy (NAP-XPS). Degree of reporting of instrument parameters

Joshua W. Pinder, Andreas Thißen, Matthew R. Linford, Paul Dietrich, Jacob Crossman, Braxton Kulbacki
article en

Abstract

A thorough understanding of x-ray photoelectron spectroscopy (XPS) results requires well-reported data collection and analysis parameters. Near ambient pressure (NAP)-XPS instrument parameters are not always reported as thoroughly as they could be in the scientific literature. This paper examines parameter reporting within the main bodies of NAP-XPS papers published from 2021 to 2023. Parameters studied include the analyzer, photon flux, x-ray source and energy, spot size, pass energy, signal integration parameters, incident angle, substrate temperature, aperture size and distance, background gas, and fitting parameters such as the background and synthetic peak shapes. On average, less than 50% of these instrument parameters are reported within the main bodies of papers, although some parameters are reported better than others. For instance, the analysis chamber pressure is reported 94% of the time, while signal integration parameters are only reported 6% of the time. Over 50% of NAP-XPS experiments are conducted at synchrotrons. Most NAP-XPS papers (92%) contain fitted data, but fewer than 50% of these papers reported peak fitting parameters. Fewer than 5% of NAP-XPS studies are operando. While this study reveals some shortcomings in reporting, because not all NAP-XPS instrument parameters are of equal importance in all experiments, and because parameter reporting also took place in the supporting information of some papers, papers that did not report all possible parameters in their main bodies do not necessarily constitute irreproducible work. Some of the experimental details and data related to a study in the supporting information sections of papers should often be included within the papers themselves, perhaps as appendices.

Journal of Vacuum Science & Technology A Vacuum Surfaces and FilmsVol. 43(6)
Brigham Young University (US), Robert Bosch (Germany) (DE)
Openalex Percentile: Top 74%
Electron and X-Ray Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.