O10 Multimodal liver assessment with endoscopic ultrasound-guided portosystemic pressure gradient (EUS-PPG), EUS-liver biopsy & variceal screening: a single centre experience

<h3>Introduction</h3> EUS-PPG has emerged as an alternative approach to assess severity of portal hypertension (PH) with the advantage of estimating portal pressure directly over conventional Hepatic Venous Pressure Gradient (HVPG). We present our experience with EUS-PPG &amp; EUS-guided liver biopsy as a single stage procedure. Surrogate markers of clinically significant PH (CSPH &gt;10mmHg) were also explored. <h3>Methods</h3> Data was prospectively collected from November 2022 to December 2024 on patients undergoing EUS-PPG using Olympus GF-UCT260 EVIS LUCERA™ echoendoscopes, 25G EchoTip Insight™ PPG measurement system and biopsy using 19G FNB. Patient demographics, indication, sedation, platelet count, PH on imaging (PHI) or endoscopy (PHE), transient elastography (TE), hepatic vein (HVP) and portal vein (PVP) pressures, EUS-PPG, biopsy adequacy (&gt;20mm and complete portal tracts (CPTs) &gt;10), technical success, complications, 30-day mortality, and patient follow-up were analysed. Pearson’s r correlation, Fisher’s exact-test and logistic regression were used for the analysis (IBM SPSS v30). <h3>Results</h3> Of 54 patients (21 women) with suspected cirrhosis who underwent EUS-PPG, 48 had simultaneous liver biopsy; 49 procedures were performed under propofol sedation. The median age and BMI were 60 (32–72) years and 27 (15.7–43.5) Kg/M2 for men, 55 (22–79) years and 27.5 (20.5–61) Kg/M2 for women. The most common indication was pre-operative risk assessment (37%) – [figure 1]. 26 patients had no evidence of PHI, 20 had low platelets count (LPLT&lt;150 X 109/L [150 – 450]) and 22 had prior TE. EUS-PPG technical success was 100%. Mean HVP was 10.33mmHg (SEM 0.82), PVP 16.79mmHg (SEM 1.14) and EUS-PPG 6.85mmHg (SEM 0.95). 22 patients (41%) had PH, with 15 (28%) CSPH. EUS-PPG correlated with platelet count (r=-0.498, p&lt;0.001) but not TE (r=0.323, p=0.142). In univariate regression analysis LPLT correlated with CSPH; (OR)=5.8 (p=0.008). LPLT with PHI (p=0.061) and PHE (p=0.058) showed a trend for correlation. In multivariate regression analysis only LPLT maintained a correlation with CSPH; (OR)=5.895 (p=0.029). 47/48 (98%) biopsy specimens were adequate for pathological diagnosis: mean length 53mm (SD 20.5) and CPTs 29.4 (SD 14.5). 9/20 pre-operative patients proceeded to surgery whilst 11 were cancelled mostly unrelated to PH. 1 patient developed micro liver abscesses, 2 had uncomplicated abdominal pain and there was no 30-day mortality. <h3>Conclusion</h3> Multimodal hepatic assessment using EUS-PPG with liver biopsy is safe and feasible. Validation against long-term outcomes and the role of other surrogate markers within the clinical pathway requires further research.

Authors

Institutions

Publication Details

Published
2025-10-01
DOI
https://doi.org/10.1136/gutjnl-2025-basl.9
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O10 Multimodal liver assessment with endoscopic ultrasound-guided portosystemic pressure gradient (EUS-PPG), EUS-liver biopsy & variceal screening: a single centre experience

Prarthana Thiagarajan, Suresh Venkatachalapathy, Andrew Baxter, Amardeep Khanna et al.
Liver Disease Diagnosis and Treatment
article

O10 Multimodal liver assessment with endoscopic ultrasound-guided portosystemic pressure gradient (EUS-PPG), EUS-liver biopsy & variceal screening: a single centre experience

Prarthana Thiagarajan, Suresh Venkatachalapathy, Andrew Baxter, Amardeep Khanna, Guruprasad Padur Aithal, Martin W. James, Evripidis Stefanidis
article en

Abstract

<h3>Introduction</h3> EUS-PPG has emerged as an alternative approach to assess severity of portal hypertension (PH) with the advantage of estimating portal pressure directly over conventional Hepatic Venous Pressure Gradient (HVPG). We present our experience with EUS-PPG &amp; EUS-guided liver biopsy as a single stage procedure. Surrogate markers of clinically significant PH (CSPH &gt;10mmHg) were also explored. <h3>Methods</h3> Data was prospectively collected from November 2022 to December 2024 on patients undergoing EUS-PPG using Olympus GF-UCT260 EVIS LUCERA™ echoendoscopes, 25G EchoTip Insight™ PPG measurement system and biopsy using 19G FNB. Patient demographics, indication, sedation, platelet count, PH on imaging (PHI) or endoscopy (PHE), transient elastography (TE), hepatic vein (HVP) and portal vein (PVP) pressures, EUS-PPG, biopsy adequacy (&gt;20mm and complete portal tracts (CPTs) &gt;10), technical success, complications, 30-day mortality, and patient follow-up were analysed. Pearson’s r correlation, Fisher’s exact-test and logistic regression were used for the analysis (IBM SPSS v30). <h3>Results</h3> Of 54 patients (21 women) with suspected cirrhosis who underwent EUS-PPG, 48 had simultaneous liver biopsy; 49 procedures were performed under propofol sedation. The median age and BMI were 60 (32–72) years and 27 (15.7–43.5) Kg/M2 for men, 55 (22–79) years and 27.5 (20.5–61) Kg/M2 for women. The most common indication was pre-operative risk assessment (37%) – [figure 1]. 26 patients had no evidence of PHI, 20 had low platelets count (LPLT&lt;150 X 109/L [150 – 450]) and 22 had prior TE. EUS-PPG technical success was 100%. Mean HVP was 10.33mmHg (SEM 0.82), PVP 16.79mmHg (SEM 1.14) and EUS-PPG 6.85mmHg (SEM 0.95). 22 patients (41%) had PH, with 15 (28%) CSPH. EUS-PPG correlated with platelet count (r=-0.498, p&lt;0.001) but not TE (r=0.323, p=0.142). In univariate regression analysis LPLT correlated with CSPH; (OR)=5.8 (p=0.008). LPLT with PHI (p=0.061) and PHE (p=0.058) showed a trend for correlation. In multivariate regression analysis only LPLT maintained a correlation with CSPH; (OR)=5.895 (p=0.029). 47/48 (98%) biopsy specimens were adequate for pathological diagnosis: mean length 53mm (SD 20.5) and CPTs 29.4 (SD 14.5). 9/20 pre-operative patients proceeded to surgery whilst 11 were cancelled mostly unrelated to PH. 1 patient developed micro liver abscesses, 2 had uncomplicated abdominal pain and there was no 30-day mortality. <h3>Conclusion</h3> Multimodal hepatic assessment using EUS-PPG with liver biopsy is safe and feasible. Validation against long-term outcomes and the role of other surrogate markers within the clinical pathway requires further research.

Queen's Medical Centre (GB)
Openalex Percentile: Top 62%
Liver Disease Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.