Ultrasound Thawing Optimization as a Novel Strategy to Improve Quality of Slowly Frozen Chicken Breast

Chicken meat is highly consumed worldwide due to its nutritional value, but its high water content and abundance of polyunsaturated fatty acids make it particularly vulnerable to structural and oxidative damage during freezing and thawing. Slow freezing, in particular, generates large ice crystals that severely impair water-holding capacity (WHC), increase drip loss, promote color deterioration, and intensify protein and lipid oxidation. Innovative thawing strategies are therefore required to mitigate these quality losses. Ultrasound (US) has been successfully applied to accelerate thawing of fast-frozen meat; however, its potential for slowly frozen chicken breast remains poorly understood. This study aimed to evaluate the effects of US-assisted thawing at two frequencies (25 and 130 kHz), two amplitudes (100% and 60%), and three operating modes (normal, sweep, and degas) on the quality of slowly frozen chicken breast. Conventional thawing required 50 min, yielding WHC of 9.87%, drip loss of 4.65%, free sulfhydryls of 16.38 µmol/g, and ∆E of 3.91. In contrast, the optimized US condition (25 kHz, 100% amplitude, sweep mode) thawed samples in only 18 min, with markedly improved WHC (23.14%), reduced drip loss (3.25%), higher preservation of free sulfhydryls (24.69 µmol/g), and minimal color change (∆E = 3.72). Conversely, less effective parameters (e.g., 130 kHz, 60% amplitude, normal mode) prolonged thawing and compromised quality, with WHC dropping to 9.96% and drip loss increasing to 9.05%. Overall, US reduced thawing time under all conditions, but quality responses depended strongly on the applied parameters. The present findings demonstrate the novelty of optimizing US frequency, amplitude, and mode for thawing slowly frozen chicken breast, highlighting sweep mode at 25 kHz and 100% amplitude as the most effective strategy. Future research should explore its scalability and industrial applicability for poultry processing.

Authors

Institutions

Publication Details

Journal
Foods
Published
2025-10-08
DOI
https://doi.org/10.3390/foods14193446
Citations
1
Primary Topic
Meat and Animal Product Quality
Type
article
Field-Weighted Citation Impact
1.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound Thawing Optimization as a Novel Strategy to Improve Quality of Slowly Frozen Chicken Breast

Bibiana Alves dos Santos, Suelen Priscila Santos, Paulo Cezar Bastianello Campagnol, Renius de Oliveira Mello et al.
1 citations
Foods
Meat and Animal Product Quality
1.19
article

Ultrasound Thawing Optimization as a Novel Strategy to Improve Quality of Slowly Frozen Chicken Breast

Bibiana Alves dos Santos, Suelen Priscila Santos, Paulo Cezar Bastianello Campagnol, Renius de Oliveira Mello, Mônica Voss, Alexandre José Cichoski, Silvino Sasso Robalo, Juliano Smanioto Barin, Bianca Campos Casarin, Cristiano Ragagnin de Menezes
article en
1 citations

Abstract

Chicken meat is highly consumed worldwide due to its nutritional value, but its high water content and abundance of polyunsaturated fatty acids make it particularly vulnerable to structural and oxidative damage during freezing and thawing. Slow freezing, in particular, generates large ice crystals that severely impair water-holding capacity (WHC), increase drip loss, promote color deterioration, and intensify protein and lipid oxidation. Innovative thawing strategies are therefore required to mitigate these quality losses. Ultrasound (US) has been successfully applied to accelerate thawing of fast-frozen meat; however, its potential for slowly frozen chicken breast remains poorly understood. This study aimed to evaluate the effects of US-assisted thawing at two frequencies (25 and 130 kHz), two amplitudes (100% and 60%), and three operating modes (normal, sweep, and degas) on the quality of slowly frozen chicken breast. Conventional thawing required 50 min, yielding WHC of 9.87%, drip loss of 4.65%, free sulfhydryls of 16.38 µmol/g, and ∆E of 3.91. In contrast, the optimized US condition (25 kHz, 100% amplitude, sweep mode) thawed samples in only 18 min, with markedly improved WHC (23.14%), reduced drip loss (3.25%), higher preservation of free sulfhydryls (24.69 µmol/g), and minimal color change (∆E = 3.72). Conversely, less effective parameters (e.g., 130 kHz, 60% amplitude, normal mode) prolonged thawing and compromised quality, with WHC dropping to 9.96% and drip loss increasing to 9.05%. Overall, US reduced thawing time under all conditions, but quality responses depended strongly on the applied parameters. The present findings demonstrate the novelty of optimizing US frequency, amplitude, and mode for thawing slowly frozen chicken breast, highlighting sweep mode at 25 kHz and 100% amplitude as the most effective strategy. Future research should explore its scalability and industrial applicability for poultry processing.

FoodsVol. 14(19)
Universidade Federal de Santa Maria (BR), Universidade Federal de Roraima (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 19%
Meat and Animal Product Quality
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.