Comparison of visual function analysis of people with low vision using three different models of augmented reality devices

We compared visual function in individuals with low vision (>20/60) using three different models of augmented reality (AR) devices: Ziru, IrisVision, and NuEyes-Pro3. The distance visual acuity (VA) was measured in high luminance high contrast (HLHC), high luminance low contrast (HLLC), low luminance high contrast (LLHC), and low luminance low contrast (LLLC) settings. The other tests were near VA, distance and near contrast sensitivity (CS), color vision, depth perception and indoor navigation. The change in visual function without and with AR devices was analyzed. Out of 27 participants, 17 were female. The mean age was 66.7 ± 18.2 years. The median baseline VA was 0.66 (0.79) logMAR in HLHC, 0.87 (0.54) logMAR in HLLC, 0.84 (0.67) logMAR in LLHC and 1.04 (0.34) logMAR in LLLC. The median baseline near VA was 0.55(0.4) logMAR, distance and near CS was 1.10(0.26) logCS, and 1.20(0.30) logCS respectively. Distance and near vision showed significant differences with both Ziru and IrisVision (p < 0.01), but not with NuEyes. There was a significant change in CS using Ziru and IrisVision for both distance and near (p < 0.05) but both reduced significantly with NuEyes (p < 0.01). During the objective identification task on the indoor environment using AR devices, head-level objects were missed more compared to waist or floor-level objects across all three models. Majority of the visual functions improved with Ziru and IrisVision, with limited improvement in certain lighting condition of distance visual acuity with NuEyes.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-10-08
DOI
https://doi.org/10.1371/journal.pone.0332085
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of visual function analysis of people with low vision using three different models of augmented reality devices

Arathy Kartha, Ronald Schuchard, Donald C. Fletcher, Sarika Gopalakrishnan
PLoS ONE
Ophthalmology and Visual Impairment Studies
article

Comparison of visual function analysis of people with low vision using three different models of augmented reality devices

Arathy Kartha, Ronald Schuchard, Donald C. Fletcher, Sarika Gopalakrishnan
article en

Abstract

We compared visual function in individuals with low vision (>20/60) using three different models of augmented reality (AR) devices: Ziru, IrisVision, and NuEyes-Pro3. The distance visual acuity (VA) was measured in high luminance high contrast (HLHC), high luminance low contrast (HLLC), low luminance high contrast (LLHC), and low luminance low contrast (LLLC) settings. The other tests were near VA, distance and near contrast sensitivity (CS), color vision, depth perception and indoor navigation. The change in visual function without and with AR devices was analyzed. Out of 27 participants, 17 were female. The mean age was 66.7 ± 18.2 years. The median baseline VA was 0.66 (0.79) logMAR in HLHC, 0.87 (0.54) logMAR in HLLC, 0.84 (0.67) logMAR in LLHC and 1.04 (0.34) logMAR in LLLC. The median baseline near VA was 0.55(0.4) logMAR, distance and near CS was 1.10(0.26) logCS, and 1.20(0.30) logCS respectively. Distance and near vision showed significant differences with both Ziru and IrisVision (p < 0.01), but not with NuEyes. There was a significant change in CS using Ziru and IrisVision for both distance and near (p < 0.05) but both reduced significantly with NuEyes (p < 0.01). During the objective identification task on the indoor environment using AR devices, head-level objects were missed more compared to waist or floor-level objects across all three models. Majority of the visual functions improved with Ziru and IrisVision, with limited improvement in certain lighting condition of distance visual acuity with NuEyes.

PLoS ONEVol. 20(10)
National Postdoctoral Association (US), Cancer Center of Kansas (US), Biotechnical Services (US), Smith-Kettlewell Eye Research Institute (US), SUNY College of Optometry (US)
Openalex Percentile: Top 62%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.