Optimisation and Mechanical Behaviour Analysis of Splice Joints in Prefabricated H-Shaped Steel Beams

This study investigated the mechanical behaviour of splice joints in prefabricated H-shaped steel beams assembled using high-strength bolts under four-point bending. Four distinct splice joint configurations were tested through mechanical experiments on prefabricated H-shaped steel beams to examine their failure modes, flexural strength, and stress distribution in the sections. Numerical simulations were performed using ANSYS finite element software to validate the experimental results. Findings reveal that specimens with double splice joints exhibit a significant reduction in both flexural bearing capacity and stiffness compared to those with single splice joints. Moreover, the distance between splice joints is a critical factor affecting the bearing capacity of the specimen. The splice joints in both the H-shaped steel and connecting plates are classified as semi-rigid connections. Additionally, the stress distribution at the splice joints deviates from the plane section assumption. A formula for calculating the deflection of spliced specimens in the elastic stage under pure bending was developed and validated with experimental data.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-10-08
DOI
https://doi.org/10.3390/buildings15193610
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimisation and Mechanical Behaviour Analysis of Splice Joints in Prefabricated H-Shaped Steel Beams

Shuaike Feng, Dawei Fan, Xin Zhang, S Yu et al.
Buildings
Structural Load-Bearing Analysis
article

Optimisation and Mechanical Behaviour Analysis of Splice Joints in Prefabricated H-Shaped Steel Beams

Shuaike Feng, Dawei Fan, Xin Zhang, S Yu, Jiaxiang Lv
article en

Abstract

This study investigated the mechanical behaviour of splice joints in prefabricated H-shaped steel beams assembled using high-strength bolts under four-point bending. Four distinct splice joint configurations were tested through mechanical experiments on prefabricated H-shaped steel beams to examine their failure modes, flexural strength, and stress distribution in the sections. Numerical simulations were performed using ANSYS finite element software to validate the experimental results. Findings reveal that specimens with double splice joints exhibit a significant reduction in both flexural bearing capacity and stiffness compared to those with single splice joints. Moreover, the distance between splice joints is a critical factor affecting the bearing capacity of the specimen. The splice joints in both the H-shaped steel and connecting plates are classified as semi-rigid connections. Additionally, the stress distribution at the splice joints deviates from the plane section assumption. A formula for calculating the deflection of spliced specimens in the elastic stage under pure bending was developed and validated with experimental data.

BuildingsVol. 15(19)
Chongqing Construction Engineering Investment Holding (China) (CN), Shandong Lianxing Energy Group (China) (CN), Shandong Jianzhu University (CN)
Natural Science Foundation of Shandong Province
Openalex Percentile: Top 70%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimisation and Mechanical Behaviour Analysis of Splice Joints in Prefabricated H-Shaped Steel Beams — Shuaike Feng, Dawei Fan, et al. · Buildings (2025) | TGRS Research Map | TGRS