Joint Altered Calibration with Linear Interpolation for Cross-Sampling

Among the methods of sampling trajectories, cross-sampling can provide more autocalibration signal (ACS) data and enables better incoherent sampling with lower gradient control system requirements. However, there were still challenges regarding magnetic field inhomogeneities. So in this study, a self-calibrated off-resonance correction is proposed to eliminate the inconsistency between the orthogonal readout data. This method employs a linear prediction operator to estimate the cross-sampled dat. The corrected data undergo the same reconstruction process as that used in conventional generalized autocalibrating partially parallel acquisitions (GRAPPA), in order to recover the missing k-space data and generate the final image. We will compare this calibration method with the traditional first-order k -space trajectory correction for cross-sampling GRAPPA and the experimental results on phantoms and human subjects demonstrate that the images reconstructed by this method exhibit fewer artifacts and higher signal-to-noise ratio (SNR).

Authors

Institutions

Publication Details

Published
2025-07-12
DOI
https://doi.org/10.1109/icsip65915.2025.11171564
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Joint Altered Calibration with Linear Interpolation for Cross-Sampling

Penghui Luo, Changliang Wang, Kaizhao Lin, Lin Chen et al.
Fault Detection and Control Systems
article

Joint Altered Calibration with Linear Interpolation for Cross-Sampling

Penghui Luo, Changliang Wang, Kaizhao Lin, Lin Chen, Jiantai Zhou, Pei Yuan
article en

Abstract

Among the methods of sampling trajectories, cross-sampling can provide more autocalibration signal (ACS) data and enables better incoherent sampling with lower gradient control system requirements. However, there were still challenges regarding magnetic field inhomogeneities. So in this study, a self-calibrated off-resonance correction is proposed to eliminate the inconsistency between the orthogonal readout data. This method employs a linear prediction operator to estimate the cross-sampled dat. The corrected data undergo the same reconstruction process as that used in conventional generalized autocalibrating partially parallel acquisitions (GRAPPA), in order to recover the missing k-space data and generate the final image. We will compare this calibration method with the traditional first-order k -space trajectory correction for cross-sampling GRAPPA and the experimental results on phantoms and human subjects demonstrate that the images reconstructed by this method exhibit fewer artifacts and higher signal-to-noise ratio (SNR).

University of Science and Technology of China (CN), Anhui Medical University (CN), Anhui Academy of Medical Sciences (CN)
Openalex Percentile: Top 65%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.