Power Balancing Services from Electrolyzer on Offshore Energy Hub

This paper explores the feasibility of integrating an Alkaline electrolyzer into an offshore energy hub to coordinate active power control among all system units. The dynamic electrolyzer model was implemented with cascaded power supply control. The physical and safety limitations (e.g. ramp rate limit) of the Alkaline electrolyzer were considered. The 4 GW offshore energy hub, with the electrolyzer model, including the coordinated control, was built and simulated in PowerFactory. The system is tested under two main fault scenarios. First, a fault disconnects the offshore wind power plants, causing the system to experience under-frequency. An HVDC converter pole fault is then considered, leading to an over-frequency situation where wind power exceeds transmission capacity. Two frequency responses, hysteresis droop controller and automatic generation control, were implemented in electrolyzer’s control scheme. The feasibility of hydrogen plants in balancing the offshore energy hub was shown in simulations.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180301
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Balancing Services from Electrolyzer on Offshore Energy Hub

Nicolaos Antonio Cutululis, Gustavo Gontijo, Daniel Müller, Mirza Nuhic et al.
Hybrid Renewable Energy Systems
article

Power Balancing Services from Electrolyzer on Offshore Energy Hub

Nicolaos Antonio Cutululis, Gustavo Gontijo, Daniel Müller, Mirza Nuhic, Nikita Taranin, Thorhildur Grimsdottir
article en

Abstract

This paper explores the feasibility of integrating an Alkaline electrolyzer into an offshore energy hub to coordinate active power control among all system units. The dynamic electrolyzer model was implemented with cascaded power supply control. The physical and safety limitations (e.g. ramp rate limit) of the Alkaline electrolyzer were considered. The 4 GW offshore energy hub, with the electrolyzer model, including the coordinated control, was built and simulated in PowerFactory. The system is tested under two main fault scenarios. First, a fault disconnects the offshore wind power plants, causing the system to experience under-frequency. An HVDC converter pole fault is then considered, leading to an over-frequency situation where wind power exceeds transmission capacity. Two frequency responses, hysteresis droop controller and automatic generation control, were implemented in electrolyzer’s control scheme. The feasibility of hydrogen plants in balancing the offshore energy hub was shown in simulations.

Ørsted (Denmark) (DK), Technical University of Denmark (DK)
Openalex Percentile: Top 69%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Power Balancing Services from Electrolyzer on Offshore Energy Hub — Nicolaos Antonio Cutululis, Gustavo Gontijo, et al. · (2025) | TGRS Research Map | TGRS