An IoT-Enabled Photoplethysmography $\text{SpO}_{2}$ Monitoring System: Design and Performance Evaluation

Oxygen saturation <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\text{SpO}_{2})$</tex> monitoring is essential for assessing respiratory and cardiovascular health, particularly in patients with heart or pulmonary conditions. Early detection of hypoxia through continuous <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> monitoring enables timely medical intervention, improving patient outcomes. However, Malaysian government hospitals and clinics face challenges such as limited access to monitoring devices, manual data entry, resource constraints, and the lack of real-time monitoring capabilities. To address these issues, this study proposes the development of an IoT -enabled <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> monitoring system using ESP32 and Blynk, enhancing patient care and facilitating seamless data sharing. The system's accuracy is evaluated using the Design of Experiment (DoE) and Analysis of Variance (ANOV A) to identify key factors influencing <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> measurement precision. Statistical analysis reveals that the index finger provides more accurate readings compared to the thumb. Additionally, environmental conditions significantly affect measurement accuracy, with low illumination yielding the highest precision. These findings contribute to the standardization of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> measurement techniques, ensuring consistency and reliability across diverse healthcare settings.

Authors

Institutions

Publication Details

Published
2025-08-22
DOI
https://doi.org/10.1109/iccsce65566.2025.11182665
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An IoT-Enabled Photoplethysmography $\text{SpO}_{2}$ Monitoring System: Design and Performance Evaluation

Juliana Md Sharif, Solahuddin Yusuf Fadhlullah, Shabinar Abdul Hamid, Siti Juliana Abu Bakar et al.
Non-Invasive Vital Sign Monitoring
article

An IoT-Enabled Photoplethysmography $\text{SpO}_{2}$ Monitoring System: Design and Performance Evaluation

Juliana Md Sharif, Solahuddin Yusuf Fadhlullah, Shabinar Abdul Hamid, Siti Juliana Abu Bakar, Ida Rahayu Mohamed Noordin, Zuraida Muhammad, Samihah Abdullah, Amir Ahzlina Jasni
article en

Abstract

Oxygen saturation <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(\text{SpO}_{2})$</tex> monitoring is essential for assessing respiratory and cardiovascular health, particularly in patients with heart or pulmonary conditions. Early detection of hypoxia through continuous <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> monitoring enables timely medical intervention, improving patient outcomes. However, Malaysian government hospitals and clinics face challenges such as limited access to monitoring devices, manual data entry, resource constraints, and the lack of real-time monitoring capabilities. To address these issues, this study proposes the development of an IoT -enabled <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> monitoring system using ESP32 and Blynk, enhancing patient care and facilitating seamless data sharing. The system's accuracy is evaluated using the Design of Experiment (DoE) and Analysis of Variance (ANOV A) to identify key factors influencing <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> measurement precision. Statistical analysis reveals that the index finger provides more accurate readings compared to the thumb. Additionally, environmental conditions significantly affect measurement accuracy, with low illumination yielding the highest precision. These findings contribute to the standardization of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{SpO}_{2}$</tex> measurement techniques, ensuring consistency and reliability across diverse healthcare settings.

Hospital Pulau Pinang (MY)
Openalex Percentile: Top 73%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.