Frequency Stability and Fast Frequency Response in Hybrid AC-DC Transmission Grids: A Comparative Study of EMT and RMS Modelling Approaches

As inverter-based generation and HVDC systems continue to be integrated into power systems, the system dynamics are becoming faster and more complex, posing new challenges for maintaining system stability and reliability. Consequently, determining the appropriate modelling approach for power system simulations – electromagnetic transient (EMT) or phasor (RMS) modelling in the context of hybrid AC-DC networks, is becoming more essential. This paper provides a comparison of the RMS and EMT modelling approaches based on a comparative study to evaluate the frequency dynamics of an AC-DC network. A model of the modified 4-machine-2-area transmission system is implemented to investigate both modelling approaches. A fast frequency response for the HVDC converters is implemented to reduce the frequency nadir and limit the rate of change of frequency (RoCoF). Various scenarios are studied to represent different dynamic phenomenon in the network. The suitability of RMS models for these various scenarios is investigated.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180575
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency Stability and Fast Frequency Response in Hybrid AC-DC Transmission Grids: A Comparative Study of EMT and RMS Modelling Approaches

Soham Choudhury, J. Hanson, X. Xiao, Anna Pfendler et al.
1 citations
HVDC Systems and Fault Protection
0.73
article

Frequency Stability and Fast Frequency Response in Hybrid AC-DC Transmission Grids: A Comparative Study of EMT and RMS Modelling Approaches

Soham Choudhury, J. Hanson, X. Xiao, Anna Pfendler, Aaron Hebing, Niklas Sturm
article en
1 citations

Abstract

As inverter-based generation and HVDC systems continue to be integrated into power systems, the system dynamics are becoming faster and more complex, posing new challenges for maintaining system stability and reliability. Consequently, determining the appropriate modelling approach for power system simulations – electromagnetic transient (EMT) or phasor (RMS) modelling in the context of hybrid AC-DC networks, is becoming more essential. This paper provides a comparison of the RMS and EMT modelling approaches based on a comparative study to evaluate the frequency dynamics of an AC-DC network. A model of the modified 4-machine-2-area transmission system is implemented to investigate both modelling approaches. A fast frequency response for the HVDC converters is implemented to reduce the frequency nadir and limit the rate of change of frequency (RoCoF). Various scenarios are studied to represent different dynamic phenomenon in the network. The suitability of RMS models for these various scenarios is investigated.

Technische Universität Darmstadt (DE), Tennet (Germany) (DE), Hitachi (Japan) (JP)
Openalex Percentile: Top 23%
HVDC Systems and Fault Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Frequency Stability and Fast Frequency Response in Hybrid AC-DC Transmission Grids: A Comparative Study of EMT and RMS Modelling Approaches — Soham Choudhury, J. Hanson, et al. · (2025) | TGRS Research Map | TGRS