Voltage Stability of Inverter-Based Systems: Impact of Parameters and Irrelevance of Line Dynamics

This paper investigates voltage stability in inverter-based power systems concerning fold and saddle-node bifurcations. An analytical expression is derived for the sensitivity of the stability margin using the normal vector to the bifurcation hypersurface. Such information enables efficient identification of effective control parameters in mitigating voltage instability. Comprehensive analysis reveals that reactive loading setpoint and current controller’s feedforward gain are the most influential parameters for enhancing voltage stability in a grid-following (GFL) inverter system, while the voltage controller’s feedforward gain plays a dominant role in a grid-forming (GFM) inverter. Notably, both theoretical and numerical results demonstrate that transmission line dynamics have no impact on fold/saddle-node bifurcations in these systems. Results in this paper provide insights for efficient analysis and control in future inverter-dominated power systems through reductions in parameter space and model complexity.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180374
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltage Stability of Inverter-Based Systems: Impact of Parameters and Irrelevance of Line Dynamics

S. Chatterjee, Sijia Geng
Islanding Detection in Power Systems
article

Voltage Stability of Inverter-Based Systems: Impact of Parameters and Irrelevance of Line Dynamics

S. Chatterjee, Sijia Geng
article en

Abstract

This paper investigates voltage stability in inverter-based power systems concerning fold and saddle-node bifurcations. An analytical expression is derived for the sensitivity of the stability margin using the normal vector to the bifurcation hypersurface. Such information enables efficient identification of effective control parameters in mitigating voltage instability. Comprehensive analysis reveals that reactive loading setpoint and current controller’s feedforward gain are the most influential parameters for enhancing voltage stability in a grid-following (GFL) inverter system, while the voltage controller’s feedforward gain plays a dominant role in a grid-forming (GFM) inverter. Notably, both theoretical and numerical results demonstrate that transmission line dynamics have no impact on fold/saddle-node bifurcations in these systems. Results in this paper provide insights for efficient analysis and control in future inverter-dominated power systems through reductions in parameter space and model complexity.

Johns Hopkins University (US)
Openalex Percentile: Top 72%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Voltage Stability of Inverter-Based Systems: Impact of Parameters and Irrelevance of Line Dynamics — S. Chatterjee, Sijia Geng · (2025) | TGRS Research Map | TGRS