Blind Calibration of Mismatch Errors in Multichannel Asynchronous Time-Interleaved ADCs

Asynchronous time interleaved (ATI) analog-to-digital converter (ADC) architectures employ pre-processing, low-pass filtering, and ADCs to simultaneously enhance the sample rate and bandwidth of acquisition systems. However, non-idealities in ATI architecture can degrade performance. This article proposes a blind calibration approach to compensate for mismatch errors in ATI systems. The advantage of this approach is that it does not interfere with the normal operation of the ADC and signal acquisition, allowing the calibration process to be performed concurrently. The approach is based entirely on the ATI output sequence, without requiring additional information or reference channels, which facilitates blind operations. It autonomously detects the sub-band in which the signal resides, allowing calibration of both single-tone and multitone signals without prior knowledge. Once the sub-band is identified, blind calibration is applied to the sampling sequence. Finally, the performance of the proposed approach was evaluated on a four-channel hardware prototype. Satisfactory results are obtained and the feasibility of the proposed approach are demonstrated.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3619216
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blind Calibration of Mismatch Errors in Multichannel Asynchronous Time-Interleaved ADCs

Sitao Mei, Yijiu Zhao, X. H. Ni, Yi Zhang et al.
IEEE Transactions on Instrumentation and Measurement
Analog and Mixed-Signal Circuit Design
article

Blind Calibration of Mismatch Errors in Multichannel Asynchronous Time-Interleaved ADCs

Sitao Mei, Yijiu Zhao, X. H. Ni, Yi Zhang, Yusen Wang
article en

Abstract

Asynchronous time interleaved (ATI) analog-to-digital converter (ADC) architectures employ pre-processing, low-pass filtering, and ADCs to simultaneously enhance the sample rate and bandwidth of acquisition systems. However, non-idealities in ATI architecture can degrade performance. This article proposes a blind calibration approach to compensate for mismatch errors in ATI systems. The advantage of this approach is that it does not interfere with the normal operation of the ADC and signal acquisition, allowing the calibration process to be performed concurrently. The approach is based entirely on the ATI output sequence, without requiring additional information or reference channels, which facilitates blind operations. It autonomously detects the sub-band in which the signal resides, allowing calibration of both single-tone and multitone signals without prior knowledge. Once the sub-band is identified, blind calibration is applied to the sampling sequence. Finally, the performance of the proposed approach was evaluated on a four-channel hardware prototype. Satisfactory results are obtained and the feasibility of the proposed approach are demonstrated.

IEEE Transactions on Instrumentation and Measurement
University of Electronic Science and Technology of China (CN)
Openalex Percentile: Top 73%
Analog and Mixed-Signal Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Blind Calibration of Mismatch Errors in Multichannel Asynchronous Time-Interleaved ADCs — Sitao Mei, Yijiu Zhao, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS