The impact of larger frequency variations on power flow in European grids: An initial case study

Increasing concerns about frequency control call for an assessment of how larger frequency variations could affect traditional power flow calculation results, i.e., the utilization of grid equipment, voltage stability, and losses in the grid. This paper presents a case study aimed at providing initial insights into this topic. The primary focus is on the impact of the frequency-dependent admittance of passive grid equipment, such as transformers, cables, and overhead lines. For two representative European test cases, the power flow is calculated under frequency variations in the range 42.5–57.5 Hz, the maximum range specified in standard EN 50160. The findings suggest that grid frequency variations in this range have only a minor influence on equipment utilization and grid losses. However, a significant effect on the computed bus voltage magnitudes is observed. This should be further explored in future studies, along with a closer evaluation of frequency-dependent power consumption, and the impact of transformer saturation.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180425
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of larger frequency variations on power flow in European grids: An initial case study

Thomas Leibfried, Johanna Geis-Schroer, Michael Suriyah
Power System Optimization and Stability
article

The impact of larger frequency variations on power flow in European grids: An initial case study

Thomas Leibfried, Johanna Geis-Schroer, Michael Suriyah
article en

Abstract

Increasing concerns about frequency control call for an assessment of how larger frequency variations could affect traditional power flow calculation results, i.e., the utilization of grid equipment, voltage stability, and losses in the grid. This paper presents a case study aimed at providing initial insights into this topic. The primary focus is on the impact of the frequency-dependent admittance of passive grid equipment, such as transformers, cables, and overhead lines. For two representative European test cases, the power flow is calculated under frequency variations in the range 42.5–57.5 Hz, the maximum range specified in standard EN 50160. The findings suggest that grid frequency variations in this range have only a minor influence on equipment utilization and grid losses. However, a significant effect on the computed bus voltage magnitudes is observed. This should be further explored in future studies, along with a closer evaluation of frequency-dependent power consumption, and the impact of transformer saturation.

Karlsruhe Institute of Technology (DE)
Openalex Percentile: Top 72%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The impact of larger frequency variations on power flow in European grids: An initial case study — Thomas Leibfried, Johanna Geis-Schroer, et al. · (2025) | TGRS Research Map | TGRS