Measurement-Based Line-Impedance Estimation in the Absence of Phasor Measurement Units

This paper proposes and compares experimentally several methods to estimate the series resistance and reactance (i.e., the transversal components of the π-model of a line) of low-voltage lines in distribution grids. It first shows that if phasor measurements are available and the grid nodal voltages and power injections are known, the problem can be formulated and solved as a conventional load flow with properly adjusted unknowns. To solve this problem, we propose an analytical derivation of the Jacobian matrix. If only RMS values are available, such as from smart meters, integrating information from multiple intervals becomes necessary, ultimately opening to least-squares estimations, widely adopted in the literature. In this context, applying the proposed Jacobian contributes to accelerating the problem resolution of existing algorithms. The methods are compared in terms of estimation performance and convergence by using measurements from an experimental distribution grid interfacing real-world components and with realistic size implemented at the Gridlab at HES-SO Valais.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180578
Citations
1
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement-Based Line-Impedance Estimation in the Absence of Phasor Measurement Units

Fabrizio Sossan, Plouton Grammatikos, Ali Mohamed Ali
1 citations
Power Line Communications and Noise
0.73
article

Measurement-Based Line-Impedance Estimation in the Absence of Phasor Measurement Units

Fabrizio Sossan, Plouton Grammatikos, Ali Mohamed Ali
article en
1 citations

Abstract

This paper proposes and compares experimentally several methods to estimate the series resistance and reactance (i.e., the transversal components of the π-model of a line) of low-voltage lines in distribution grids. It first shows that if phasor measurements are available and the grid nodal voltages and power injections are known, the problem can be formulated and solved as a conventional load flow with properly adjusted unknowns. To solve this problem, we propose an analytical derivation of the Jacobian matrix. If only RMS values are available, such as from smart meters, integrating information from multiple intervals becomes necessary, ultimately opening to least-squares estimations, widely adopted in the literature. In this context, applying the proposed Jacobian contributes to accelerating the problem resolution of existing algorithms. The methods are compared in terms of estimation performance and convergence by using measurements from an experimental distribution grid interfacing real-world components and with realistic size implemented at the Gridlab at HES-SO Valais.

HES-SO Valais-Wallis (CH)
Openalex Percentile: Top 23%
Power Line Communications and Noise
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.