Utilizing Multi-PPG-Sensor Site Information in a Localized Wrist Area for Improving Cuffless Blood Pressure Estimation

Blood pressure (BP) measurement accuracy is highly sensitive to sensor placement. To address this, we investigated the effect of multi-sensor sites on BP estimation using a 9-channel single-wavelength photoplethysmography (PPG) sensor array placed within a localized wrist area. As a starting point, we analyzed the variability of 9 PPG features across channels, revealing notable site-specific variations, with amplitude-based features showing greater sensitivity. Leveraging these findings, we developed 3M-BPNet, which processes PPG signals through varying channel/site counts. The network incorporates signal trimming and Bayesian optimization for channel-weight allocation, followed by a Random Forest Regression (RFR) model with personalized calibration. Tested on 121 subjects, the 3M-BPNet achieved mean absolute errors (MAEs) of 4.84 mmHg for systolic BP (SBP) and 3.28 mmHg for diastolic BP (DBP), outperforming a standard RFR model. Notably, BP estimation accuracy improved as the channel counts increased from 1 to 5, then declined beyond 5. The optimal 5-channel combination (C5- C6-C7-C8-C9), located near the radial artery, yielded MAEs of 1.33 mmHg for SBP and 1.16 mmHg for DBP, corresponding to accuracy gains of 72.6% for SBP and 73.2% for DBP over the single-channel setup (P < 0.001 for both MAE_SBP and MAE_DBP). Compared with the best prior PPG-based BP estimation results, our method reduced SBP MAE by 71.9% and DBP MAE by 51.3%. These findings highlight the critical role of sensor location in PPG-based BP estimation, suggesting that optimized sensor placement can enhance the accuracy and guide the design of wearable cuffless BP devices, thereby advancing hypertension management.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3619070
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing Multi-PPG-Sensor Site Information in a Localized Wrist Area for Improving Cuffless Blood Pressure Estimation

Nan Ji, Rushuang Zhou, Yuan‐Ting Zhang, Ting Xiang et al.
1 citations
IEEE Journal of Biomedical and Health Informatics
Non-Invasive Vital Sign Monitoring
0.67
article

Utilizing Multi-PPG-Sensor Site Information in a Localized Wrist Area for Improving Cuffless Blood Pressure Estimation

Nan Ji, Rushuang Zhou, Yuan‐Ting Zhang, Ting Xiang, Zijun Liu
article en
1 citations

Abstract

Blood pressure (BP) measurement accuracy is highly sensitive to sensor placement. To address this, we investigated the effect of multi-sensor sites on BP estimation using a 9-channel single-wavelength photoplethysmography (PPG) sensor array placed within a localized wrist area. As a starting point, we analyzed the variability of 9 PPG features across channels, revealing notable site-specific variations, with amplitude-based features showing greater sensitivity. Leveraging these findings, we developed 3M-BPNet, which processes PPG signals through varying channel/site counts. The network incorporates signal trimming and Bayesian optimization for channel-weight allocation, followed by a Random Forest Regression (RFR) model with personalized calibration. Tested on 121 subjects, the 3M-BPNet achieved mean absolute errors (MAEs) of 4.84 mmHg for systolic BP (SBP) and 3.28 mmHg for diastolic BP (DBP), outperforming a standard RFR model. Notably, BP estimation accuracy improved as the channel counts increased from 1 to 5, then declined beyond 5. The optimal 5-channel combination (C5- C6-C7-C8-C9), located near the radial artery, yielded MAEs of 1.33 mmHg for SBP and 1.16 mmHg for DBP, corresponding to accuracy gains of 72.6% for SBP and 73.2% for DBP over the single-channel setup (P < 0.001 for both MAE_SBP and MAE_DBP). Compared with the best prior PPG-based BP estimation results, our method reduced SBP MAE by 71.9% and DBP MAE by 51.3%. These findings highlight the critical role of sensor location in PPG-based BP estimation, suggesting that optimized sensor placement can enhance the accuracy and guide the design of wearable cuffless BP devices, thereby advancing hypertension management.

IEEE Journal of Biomedical and Health InformaticsVol. PP
City University of Hong Kong (HK), Chinese University of Hong Kong (HK)
Openalex Percentile: Top 26%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.