Effects of Cavitation on Vibration of Sleeve Control Valve

Abstract Control valves are critical components in fluid industrial systems. They are installed on pressure pipes, responsible for flow and pressure regulating. In applications such as nuclear power, thermal power generation, and aviation, these valves often suffer significant pressure differences, which can cause them to cavitate. Cavitation is a phenomenon of vapor formation induced by pressure change in liquid, and it often leads to the intense valve vibrations, which can adversely affect the stability and safety of the system. Therefore, understanding the interaction between cavitation and vibration in control valves is essential for ensuring system reliability. This study chooses a sleeve control valve with throttling windows designed for nuclear power field. An experimental approach was used to measure valve vibrations under various pressure conditions. The inlet pressure was kept constant at 300 kPa, while the outlet pressure was reduced to create different pressure drops. This is because the possibility of cavitation rises with the increase in pressure differences. Vibration signals under various pressure conditions were recorded by vibration acceleration sensors, and the Root Mean Square (RMS) values were calculated to quantify vibration intensity. The results show that when the pressure differences keep rising, vibration intensity sharply increases under certain pressure conditions, coinciding with cavitation bubble collapse inside the valve. Several experimental tests at different valve openings confirmed the results. To further explore the relationship between cavitation and vibration, simulations were conducted under the same experimental conditions. The vapor volume fraction and vapor distribution in the valve under the experimental conditions are obtained. The simulations were validated by experimental results about the flow rate. The simulation results show a clear link between cavitation and the increases in vibration intensity. With the formation of the cavitation bubbles, vibration intensity increases sharply. Conversely, when vibrations increase steadily, cavitation bubbles have likely reached saturation. This result directly shows that the sharp increase in vibration is related to the cavitation process in the sleeve control valve. The study also found that cavitation-induced vibrations are significantly stronger than those caused by regular fluid flow. These findings provide evidence for the research on the causes of vibration in sleeve control valves. The results are of significance for future efforts to reduce cavitation and vibrations in sleeve control valves with throttling windows, improving the stability and safety of industrial systems.

Authors

Institutions

Publication Details

Published
2025-07-20
DOI
https://doi.org/10.1115/pvp2025-154529
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Cavitation on Vibration of Sleeve Control Valve

Qinglie He, Kan Sheng, Xiang Lin Gu, Jin-yuan Qian et al.
Engineering Applied Research
article

Effects of Cavitation on Vibration of Sleeve Control Valve

Qinglie He, Kan Sheng, Xiang Lin Gu, Jin-yuan Qian, Chuang Liu, Longxiang Wang, Shen-zhe Zhang, Weiliang Pan
article en

Abstract

Abstract Control valves are critical components in fluid industrial systems. They are installed on pressure pipes, responsible for flow and pressure regulating. In applications such as nuclear power, thermal power generation, and aviation, these valves often suffer significant pressure differences, which can cause them to cavitate. Cavitation is a phenomenon of vapor formation induced by pressure change in liquid, and it often leads to the intense valve vibrations, which can adversely affect the stability and safety of the system. Therefore, understanding the interaction between cavitation and vibration in control valves is essential for ensuring system reliability. This study chooses a sleeve control valve with throttling windows designed for nuclear power field. An experimental approach was used to measure valve vibrations under various pressure conditions. The inlet pressure was kept constant at 300 kPa, while the outlet pressure was reduced to create different pressure drops. This is because the possibility of cavitation rises with the increase in pressure differences. Vibration signals under various pressure conditions were recorded by vibration acceleration sensors, and the Root Mean Square (RMS) values were calculated to quantify vibration intensity. The results show that when the pressure differences keep rising, vibration intensity sharply increases under certain pressure conditions, coinciding with cavitation bubble collapse inside the valve. Several experimental tests at different valve openings confirmed the results. To further explore the relationship between cavitation and vibration, simulations were conducted under the same experimental conditions. The vapor volume fraction and vapor distribution in the valve under the experimental conditions are obtained. The simulations were validated by experimental results about the flow rate. The simulation results show a clear link between cavitation and the increases in vibration intensity. With the formation of the cavitation bubbles, vibration intensity increases sharply. Conversely, when vibrations increase steadily, cavitation bubbles have likely reached saturation. This result directly shows that the sharp increase in vibration is related to the cavitation process in the sleeve control valve. The study also found that cavitation-induced vibrations are significantly stronger than those caused by regular fluid flow. These findings provide evidence for the research on the causes of vibration in sleeve control valves. The results are of significance for future efforts to reduce cavitation and vibrations in sleeve control valves with throttling windows, improving the stability and safety of industrial systems.

Valve (United States) (US), Zhejiang Institute of Special Equipment Inspection (CN), Zhejiang University (CN)
Openalex Percentile: Top 70%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.