Safety and performance implications of lithium plating induced by sub-zero temperature cycling of lithium-ion batteries

The operation of lithium-ion cells at sub-zero temperatures can result in the deposition of metallic lithium onto the surface of the negative electrode. The resulting lithium deposits have substantial ramifications for the performance and safety of the cell, with rapid capacity fade and reduced thermal stability both exhibited in cells aged under these conditions. In this study, it is found that extending the cycling temperatures of these cells to sub-zero temperatures results in a change in plating behaviour, with cells cycled at −10 °C exhibiting reversible plating behaviour and cells cycled at −20 °C plating irreversibly instead. Additionally, the nature of the plating is observed to transition from reversible to irreversible with progressive ageing in the cells cycled at −10 °C. Using operando electrochemical analysis such as voltage relaxation and Coulombic efficiency (CE) measurement, characteristics of the degradation are revealed. Electrochemical impedance spectroscopy (EIS) is also employed between cycles to provide information on the changes in internal cell processes due to plating. Ex-situ investigations complement the analysis allowing images of electrode condition to be collected. In-situ X-ray computed tomography further highlights how lithium plating compromises the structural integrity of the internal cell architecture, leading to increased safety concerns. Testing the aged cells with accelerated rate calorimetry also shows that the presence of more strongly reductive metallic lithium within a cell results in lower onset temperatures for self-heating and thermal runaway, plus an increased potential for projectiles during failure. • Degradation and safety of Li-ion cells at low temperatures examined. • Influence of temperature on Li plating on safety explored. • Jelly roll collapse due to Li-plating observed. • Multi-technique characterisation details increased safety risk at low temperatures.

Authors

Institutions

Publication Details

Journal
Journal of Power Sources
Published
2025-10-08
DOI
https://doi.org/10.1016/j.jpowsour.2025.238565
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety and performance implications of lithium plating induced by sub-zero temperature cycling of lithium-ion batteries

James B. Robinson, Francesco Iacoviello, Hamish Thomas Reid, Paul Robert Shearing et al.
Journal of Power Sources
Advanced Battery Technologies Research
article

Safety and performance implications of lithium plating induced by sub-zero temperature cycling of lithium-ion batteries

James B. Robinson, Francesco Iacoviello, Hamish Thomas Reid, Paul Robert Shearing, Gareth Hinds, Rhodri Jervis, Mark Buckwell, Arthur Fordham, Kofi Coke, Michael J. Johnson, Charles Kirchner-Burles
article en

Abstract

The operation of lithium-ion cells at sub-zero temperatures can result in the deposition of metallic lithium onto the surface of the negative electrode. The resulting lithium deposits have substantial ramifications for the performance and safety of the cell, with rapid capacity fade and reduced thermal stability both exhibited in cells aged under these conditions. In this study, it is found that extending the cycling temperatures of these cells to sub-zero temperatures results in a change in plating behaviour, with cells cycled at −10 °C exhibiting reversible plating behaviour and cells cycled at −20 °C plating irreversibly instead. Additionally, the nature of the plating is observed to transition from reversible to irreversible with progressive ageing in the cells cycled at −10 °C. Using operando electrochemical analysis such as voltage relaxation and Coulombic efficiency (CE) measurement, characteristics of the degradation are revealed. Electrochemical impedance spectroscopy (EIS) is also employed between cycles to provide information on the changes in internal cell processes due to plating. Ex-situ investigations complement the analysis allowing images of electrode condition to be collected. In-situ X-ray computed tomography further highlights how lithium plating compromises the structural integrity of the internal cell architecture, leading to increased safety concerns. Testing the aged cells with accelerated rate calorimetry also shows that the presence of more strongly reductive metallic lithium within a cell results in lower onset temperatures for self-heating and thermal runaway, plus an increased potential for projectiles during failure. • Degradation and safety of Li-ion cells at low temperatures examined. • Influence of temperature on Li plating on safety explored. • Jelly roll collapse due to Li-plating observed. • Multi-technique characterisation details increased safety risk at low temperatures.

Journal of Power SourcesVol. 660
Oxford Brookes University (GB), National Physical Laboratory (GB), The Faraday Institution (GB), University College London (GB)
Openalex Percentile: Top 69%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.