Minimizing quantification uncertainty in nanoplasmonic platforms: Multifunctional <scp> MoS <sub>2</sub> </scp> ‐integration for precise biomarker determination

Abstract Despite growing interest in nanoplasmonic biosensors—particularly surface‐enhanced Raman spectroscopy (SERS) platforms—their potential has been limited by high quantification variability rooted in poor uniformity. Previous approaches to address this, such as incorporating internal standards (ISs), often sacrificed sensitivity for uniformity or lacked a clear analytical basis for accurate quantification. Here, a novel approach of integrating MoS 2 into a SERS platform is introduced, with a focus on mitigating spot‐to‐spot relative standard deviation (RSD) and improving quantification accuracy. While maintaining the well‐known enhanced sensitivity of MoS 2 , the Raman signal from a uniform monolayer is utilized to calibrate signal variations. As a result, the platform achieves the lowest RSD (5.29%) among MoS 2 ‐based systems, while offering the highest level of sensitivity in rhodamine 6G (R6G) measurements. For albumin, the target proteinuria biomarker, MoS 2 ‐based normalization outperforms conventional wafer‐based methods and achieves a 42% RSD reduction over non‐normalization because the atomic thickness MoS 2 enables precise plasmonic calibration. Furthermore, a consistent, exponential relationship between MoS 2 signal intensity and albumin concentration is discovered. Quantification trends are consequently highly predictable, resulting in a 4.8‐fold increase in data separability. This quantification approach is shown to be effective for albumin mixed in artificial urine under various laser conditions, highlighting the practical potential of our platform for early‐stage monitoring of biomarkers. image

Authors

Institutions

Publication Details

Journal
InfoMat
Published
2025-10-08
DOI
https://doi.org/10.1002/inf2.70088
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimizing quantification uncertainty in nanoplasmonic platforms: Multifunctional MoS 2 ‐integration for precise biomarker determination

Seunghee H. Cho, Jeongwon Park, Hanhwi Jang, Han Young Woo et al.
1 citations
InfoMat
Advanced biosensing and bioanalysis techniques
0.81
article

Minimizing quantification uncertainty in nanoplasmonic platforms: Multifunctional MoS 2 ‐integration for precise biomarker determination

Seunghee H. Cho, Jeongwon Park, Hanhwi Jang, Han Young Woo, Seung‐Kyun Lee, Yeon Sik Jung, Minjae Ku, Kibum Kang, Gyeongcheon Jo, Seongdae Kwon
article en
1 citations

Abstract

Abstract Despite growing interest in nanoplasmonic biosensors—particularly surface‐enhanced Raman spectroscopy (SERS) platforms—their potential has been limited by high quantification variability rooted in poor uniformity. Previous approaches to address this, such as incorporating internal standards (ISs), often sacrificed sensitivity for uniformity or lacked a clear analytical basis for accurate quantification. Here, a novel approach of integrating MoS 2 into a SERS platform is introduced, with a focus on mitigating spot‐to‐spot relative standard deviation (RSD) and improving quantification accuracy. While maintaining the well‐known enhanced sensitivity of MoS 2 , the Raman signal from a uniform monolayer is utilized to calibrate signal variations. As a result, the platform achieves the lowest RSD (5.29%) among MoS 2 ‐based systems, while offering the highest level of sensitivity in rhodamine 6G (R6G) measurements. For albumin, the target proteinuria biomarker, MoS 2 ‐based normalization outperforms conventional wafer‐based methods and achieves a 42% RSD reduction over non‐normalization because the atomic thickness MoS 2 enables precise plasmonic calibration. Furthermore, a consistent, exponential relationship between MoS 2 signal intensity and albumin concentration is discovered. Quantification trends are consequently highly predictable, resulting in a 4.8‐fold increase in data separability. This quantification approach is shown to be effective for albumin mixed in artificial urine under various laser conditions, highlighting the practical potential of our platform for early‐stage monitoring of biomarkers. image

InfoMatVol. 8(3)
Korea Advanced Institute of Science and Technology (KR)
Openalex Percentile: Top 23%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.