Quantifying the stability of the probe current of scanning electron microscopes

Abstract Probe current stability in a scanning electron microscopy (SEM) is a critical factor related to the realization of high-resolution imaging and accurate nanoscale metrology, including critical dimension measurements and depth estimations. While prior research has predominantly focused on noise sources and long-term drift, systematic quantifications of sensitivity coefficients and measurement uncertainties across various electron gun configurations remain insufficient. Without a clear understanding of how structural parameters such as the tip radius and extractor gap affect probe current stability, optimizing electron sources for advanced metrology continues to be a challenge. Moreover, the lack of experimental validation hinders reliable uncertainty analyses. In this study, we evaluate both short-term and long-term probe current stability levels for thermal field emission and cold field emission sources using Allan deviation and autocorrelation function analyses. Sensitivity coefficients with respect to the extraction voltage are systematically simulated over a range of tip radius and extractor gap distances, revealing direct correlations between geometric design parameters and current stability levels. Experimental measurements are combined with simulation results to quantify the combined standard uncertainty and expanded uncertainty of the probe current for various electron gun configurations. These results establish a clear correlation between emission structure parameters and probe current variations, providing a practical basis for the optimization of electron-optical systems in SEM applications for improved stability and metrology performance outcomes.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-10-01
DOI
https://doi.org/10.1088/1681-7575/ae10c1
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying the stability of the probe current of scanning electron microscopes

Youngkwon Haam, Junhyeok Hwang, Dal‐Jae Yun, Takashi Ogawa et al.
Metrologia
Electron and X-Ray Spectroscopy Techniques
article

Quantifying the stability of the probe current of scanning electron microscopes

Youngkwon Haam, Junhyeok Hwang, Dal‐Jae Yun, Takashi Ogawa, Haewon Jung, In‐Yong Park, H. Lee, Hoon Kang, Jeong-Woong Lee
article en

Abstract

Abstract Probe current stability in a scanning electron microscopy (SEM) is a critical factor related to the realization of high-resolution imaging and accurate nanoscale metrology, including critical dimension measurements and depth estimations. While prior research has predominantly focused on noise sources and long-term drift, systematic quantifications of sensitivity coefficients and measurement uncertainties across various electron gun configurations remain insufficient. Without a clear understanding of how structural parameters such as the tip radius and extractor gap affect probe current stability, optimizing electron sources for advanced metrology continues to be a challenge. Moreover, the lack of experimental validation hinders reliable uncertainty analyses. In this study, we evaluate both short-term and long-term probe current stability levels for thermal field emission and cold field emission sources using Allan deviation and autocorrelation function analyses. Sensitivity coefficients with respect to the extraction voltage are systematically simulated over a range of tip radius and extractor gap distances, revealing direct correlations between geometric design parameters and current stability levels. Experimental measurements are combined with simulation results to quantify the combined standard uncertainty and expanded uncertainty of the probe current for various electron gun configurations. These results establish a clear correlation between emission structure parameters and probe current variations, providing a practical basis for the optimization of electron-optical systems in SEM applications for improved stability and metrology performance outcomes.

MetrologiaVol. 62(5)
Korea Research Institute of Standards and Science (KR)
Openalex Percentile: Top 74%
Electron and X-Ray Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.