The Comparison of Radiation Attenuation Correction Techniques for Relative Renal Function in Renal Cortical Scintigraphy

Background: Renal cortical scintigraphy using Tc-99m Dimercaptosuccinic acid (Tc-99m DMSA) is the detection of cortical abnormalities. In addition, relative renal function (RRF) is performed by DMSA scintigraphy and estimated from the radiopharmaceutical uptake in both kidneys with radiation attenuation correction. Generally, attenuation correction is calculated from mathematic methods with kidney depth correction for an accurate renal function value. Objective: The purpose of this research was to study the correlation of the RRF with radiation attenuation correction by geometric mean (GM) method and kidney depth correction by Beer-Lambert law equation. Methods: Researchers studied in the spherical phantom, kidney phantom and patient’s data using planar images from gamma camera imaging to evaluate the RRF. All study, the renal region of interest (ROI) is created from planar image for activity counts calculation. Results: The results are subtracted background and corrected the radiation attenuation using GM and kidney depth correction by Beer-Lambert law. Phantom studies, the RRF from GM radiation attenuation correction was consistent with kidney depth correction by Beer-Lambert law equation and true renal depth (ICC > 0.84). The patient’s study showed the RRF from GM method related to the other kidney depth correction methods (R2 > 0.95) and GM method was not significantly different from other renal depth correction methods (P > 0.05, ICC > 0.95). Conclusion: Finally, radiation attenuation is corrected by GM and kidney depth correction by Beer-Lambert law equation method can be used to estimate RRF appropriately in renal cortical scintigraphy.

Authors

Publication Details

Journal
Chulalongkorn Medical Journal
Published
2025-10-07
DOI
https://doi.org/10.56808/2673-060x.5497
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Comparison of Radiation Attenuation Correction Techniques for Relative Renal Function in Renal Cortical Scintigraphy

Sorasak Wanitchanan, Trai Chairat, Tanawat Sontrapornpol, Thunyaluk Sawatnatee et al.
Chulalongkorn Medical Journal
Radiation Dose and Imaging
article

The Comparison of Radiation Attenuation Correction Techniques for Relative Renal Function in Renal Cortical Scintigraphy

Sorasak Wanitchanan, Trai Chairat, Tanawat Sontrapornpol, Thunyaluk Sawatnatee, Benchamat Phromphao
article en

Abstract

Background: Renal cortical scintigraphy using Tc-99m Dimercaptosuccinic acid (Tc-99m DMSA) is the detection of cortical abnormalities. In addition, relative renal function (RRF) is performed by DMSA scintigraphy and estimated from the radiopharmaceutical uptake in both kidneys with radiation attenuation correction. Generally, attenuation correction is calculated from mathematic methods with kidney depth correction for an accurate renal function value. Objective: The purpose of this research was to study the correlation of the RRF with radiation attenuation correction by geometric mean (GM) method and kidney depth correction by Beer-Lambert law equation. Methods: Researchers studied in the spherical phantom, kidney phantom and patient’s data using planar images from gamma camera imaging to evaluate the RRF. All study, the renal region of interest (ROI) is created from planar image for activity counts calculation. Results: The results are subtracted background and corrected the radiation attenuation using GM and kidney depth correction by Beer-Lambert law. Phantom studies, the RRF from GM radiation attenuation correction was consistent with kidney depth correction by Beer-Lambert law equation and true renal depth (ICC > 0.84). The patient’s study showed the RRF from GM method related to the other kidney depth correction methods (R2 > 0.95) and GM method was not significantly different from other renal depth correction methods (P > 0.05, ICC > 0.95). Conclusion: Finally, radiation attenuation is corrected by GM and kidney depth correction by Beer-Lambert law equation method can be used to estimate RRF appropriately in renal cortical scintigraphy.

Chulalongkorn Medical JournalVol. 69(5)
Openalex Percentile: Top 58%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Comparison of Radiation Attenuation Correction Techniques for Relative Renal Function in Renal Cortical Scintigraphy — Sorasak Wanitchanan, Trai Chairat, et al. · Chulalongkorn Medical Journal (2025) | TGRS Research Map | TGRS