Replication Analysis of Shaking Table Test for Floating Seismic Isolation System

Abstract This study presents the replication analysis of the shaking test for floating seismic isolation system (FSIS) conducted using the world largest shaking table “E-Defense” in Japan. The FSIS technology can provide prominent seismic isolation effects not only for the horizontal direction but also for the vertical direction. One of the unique features in FSIS is the air cavity rooms equipped with the bottom side of the floating structure. These air cavity rooms play a role of suspensions reducing resonant frequency of the floating structures in the vertical motions so that the seismic isolation effect can be obtained for the vertical direction. Although the seismic isolation effects were substantiated by the shaking tests, there were some limitations in the shaking test. In this study, the dynamic analyses have been performed to comprehend the dynamic behaviors of the floating structures in the shaking test by replicating the same situation as the shaking test, and to evaluate the actual seismic isolation performance by eliminating factors disturbing the seismic isolation effects in the shaking test. Through the replication analyses, main dynamic modes of the FSIS test facilities could be represented. Also, the simulation results revealed that the bulging effect of the pool vessel augments the response of the floating structure so that the seismic isolation effects were reduced. This effect was underpinned by conducting the sensitivity analyses on the condition that the pool vessel was changed to be stiffer. This fact will contribute to the development of the seismic analysis methodology applicable to the actual design of FSIS paired nuclear power plants.

Authors

Institutions

Publication Details

Published
2025-07-20
DOI
https://doi.org/10.1115/pvp2025-152624
Primary Topic
Structural Integrity and Reliability Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Replication Analysis of Shaking Table Test for Floating Seismic Isolation System

Akihito Otani, Yuki Sato, Satoru Kai, Shunji Kataoka et al.
Structural Integrity and Reliability Analysis
article

Replication Analysis of Shaking Table Test for Floating Seismic Isolation System

Akihito Otani, Yuki Sato, Satoru Kai, Shunji Kataoka, Xing L. Yan, Yasutomi Morimoto, Issei Ota
article en

Abstract

Abstract This study presents the replication analysis of the shaking test for floating seismic isolation system (FSIS) conducted using the world largest shaking table “E-Defense” in Japan. The FSIS technology can provide prominent seismic isolation effects not only for the horizontal direction but also for the vertical direction. One of the unique features in FSIS is the air cavity rooms equipped with the bottom side of the floating structure. These air cavity rooms play a role of suspensions reducing resonant frequency of the floating structures in the vertical motions so that the seismic isolation effect can be obtained for the vertical direction. Although the seismic isolation effects were substantiated by the shaking tests, there were some limitations in the shaking test. In this study, the dynamic analyses have been performed to comprehend the dynamic behaviors of the floating structures in the shaking test by replicating the same situation as the shaking test, and to evaluate the actual seismic isolation performance by eliminating factors disturbing the seismic isolation effects in the shaking test. Through the replication analyses, main dynamic modes of the FSIS test facilities could be represented. Also, the simulation results revealed that the bulging effect of the pool vessel augments the response of the floating structure so that the seismic isolation effects were reduced. This effect was underpinned by conducting the sensitivity analyses on the condition that the pool vessel was changed to be stiffer. This fact will contribute to the development of the seismic analysis methodology applicable to the actual design of FSIS paired nuclear power plants.

Japan Atomic Energy Agency (JP), IHI Corporation (United States) (US), IHI Corporation (United Kingdom) (GB), IHI Corporation (Czechia) (CZ), JGC (Japan) (JP)
Openalex Percentile: Top 71%
Structural Integrity and Reliability Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.