Submarine Pipeline Outer Pipe Leakage Detection Method Based On Percussive Acoustic Signals

Abstract Submarine pipelines predominantly employ a double-layer insulation structure. Corrosion or damage to the outer pipe can lead to water ingress into the interlayer, ultimately resulting in the failure of the intermediate insulation layer due to submersion in seawater. Conventional detection methods (manual inspection, infrared thermal imaging, and fiber optic detection) are hindered by the influence of the complex marine environment and technical limitations, thereby failing to ensure the effectiveness of leakage detection for the outer pipe of submarine pipelines. This paper focuses on the intelligent acoustic internal detection technology. The innovation of this paper is proposing a novel leakage detection method for submarine pipeline outer pipes based on percussive acoustic signals. This method is supported by a detection experiment of submarine pipeline outer pipe leakage. Firstly, the percussive acoustic signals under two states of normal and outer pipe leakage (water ingress into the insulation layer) are collected in the experiment. Secondly, the acoustic signals are segmented and processed to construct a detection dataset. Finally, the time-domain and frequency-domain distributions of the processed signals are utilized as inputs to a dual-channel convolutional neural network (DC-CNN) for the leakage detection of the outer pipe of submarine pipelines. The experimental results demonstrate that the detection method based on percussive acoustic signals can achieve effective leakage diagnosis of the outer pipe of submarine pipelines with an accuracy rate of 95.83%, thereby providing a technical foundation for the subsequent development of intelligent acoustic internal detection equipment.

Authors

Institutions

Publication Details

Published
2025-07-20
DOI
https://doi.org/10.1115/pvp2025-154466
Primary Topic
Structural Integrity and Reliability Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Submarine Pipeline Outer Pipe Leakage Detection Method Based On Percussive Acoustic Signals

Laibin Zhang, Yifan Wang, Hao Liu, Shaohua Dong et al.
Structural Integrity and Reliability Analysis
article

Submarine Pipeline Outer Pipe Leakage Detection Method Based On Percussive Acoustic Signals

Laibin Zhang, Yifan Wang, Hao Liu, Shaohua Dong, Xu Zhang, Qingqing Xu
article en

Abstract

Abstract Submarine pipelines predominantly employ a double-layer insulation structure. Corrosion or damage to the outer pipe can lead to water ingress into the interlayer, ultimately resulting in the failure of the intermediate insulation layer due to submersion in seawater. Conventional detection methods (manual inspection, infrared thermal imaging, and fiber optic detection) are hindered by the influence of the complex marine environment and technical limitations, thereby failing to ensure the effectiveness of leakage detection for the outer pipe of submarine pipelines. This paper focuses on the intelligent acoustic internal detection technology. The innovation of this paper is proposing a novel leakage detection method for submarine pipeline outer pipes based on percussive acoustic signals. This method is supported by a detection experiment of submarine pipeline outer pipe leakage. Firstly, the percussive acoustic signals under two states of normal and outer pipe leakage (water ingress into the insulation layer) are collected in the experiment. Secondly, the acoustic signals are segmented and processed to construct a detection dataset. Finally, the time-domain and frequency-domain distributions of the processed signals are utilized as inputs to a dual-channel convolutional neural network (DC-CNN) for the leakage detection of the outer pipe of submarine pipelines. The experimental results demonstrate that the detection method based on percussive acoustic signals can achieve effective leakage diagnosis of the outer pipe of submarine pipelines with an accuracy rate of 95.83%, thereby providing a technical foundation for the subsequent development of intelligent acoustic internal detection equipment.

China University of Petroleum, Beijing (CN)
Openalex Percentile: Top 71%
Structural Integrity and Reliability Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Submarine Pipeline Outer Pipe Leakage Detection Method Based On Percussive Acoustic Signals — Laibin Zhang, Yifan Wang, et al. · (2025) | TGRS Research Map | TGRS