DC Fault Management Strategies in Hybrid MMC-based HVdc Systems

The hybrid half-bridge (HB) and full-bridge (FB) modular multilevel converter (MMC) is recognized for its capability to handle dc faults in high-voltage dc (HVdc) systems. During a dc fault, various fault management strategies are employed in the hybrid MMC to reduce the dc-side voltage and the fault current. These strategies have a significant impact on the performance of the MMC, particularly on the submodule (SM) capacitor voltages. This paper investigates different fault management strategies employed in hybrid MMC-based HVdc systems. The fault management strategies considered in this paper are based on the dc fault current management achieved through active control and blocking SMs. In the active control mode, the dc side voltage of the MMC is managed in a way to reduce the fault current after fault detection, while keep the control on the MMC. In another strategy, all the power switches are turned off temporarily, leading to the injection of counter-emf voltage by FB-SMs and current reduction. However, it will lose the control temporarily on the MMC current and voltages. In this paper, different aspects of these two techniques are compared, and the validity of the comparison is proved through simulation in Matlab/Simulink environment and experiments on a scaled-down laboratory prototype.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180403
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC Fault Management Strategies in Hybrid MMC-based HVdc Systems

Marco Liserre, Hossein Iman‐Eini, Sattar Bazyar, Saeed Norouztamar
HVDC Systems and Fault Protection
article

DC Fault Management Strategies in Hybrid MMC-based HVdc Systems

Marco Liserre, Hossein Iman‐Eini, Sattar Bazyar, Saeed Norouztamar
article en

Abstract

The hybrid half-bridge (HB) and full-bridge (FB) modular multilevel converter (MMC) is recognized for its capability to handle dc faults in high-voltage dc (HVdc) systems. During a dc fault, various fault management strategies are employed in the hybrid MMC to reduce the dc-side voltage and the fault current. These strategies have a significant impact on the performance of the MMC, particularly on the submodule (SM) capacitor voltages. This paper investigates different fault management strategies employed in hybrid MMC-based HVdc systems. The fault management strategies considered in this paper are based on the dc fault current management achieved through active control and blocking SMs. In the active control mode, the dc side voltage of the MMC is managed in a way to reduce the fault current after fault detection, while keep the control on the MMC. In another strategy, all the power switches are turned off temporarily, leading to the injection of counter-emf voltage by FB-SMs and current reduction. However, it will lose the control temporarily on the MMC current and voltages. In this paper, different aspects of these two techniques are compared, and the validity of the comparison is proved through simulation in Matlab/Simulink environment and experiments on a scaled-down laboratory prototype.

Christian-Albrechts-Universität zu Kiel (DE)
Openalex Percentile: Top 72%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.