Fast and Adaptive Loss of Field Detection in Synchronous Generators Using Real-Time Monitoring and Genetic Algorithm

Loss of Field (LOF) is a common fault in synchronous machine operation, often resulting from short circuits in the field winding or inadvertent tripping of the field breaker. Effective protection of synchronous generators against LOF is crucial due to its potential to cause generator and grid instability, reduced operational efficiency, and significant machine damage. This paper presents an advanced method for initiating a trip signal to the Loss of Excitation (LOE) relay in synchronous generators, utilizing real-time data monitoring and adaptive techniques for reliable detection. The proposed method leverages variations in rotor angle, generator voltage, and reactive power to promptly identify LOF conditions, enabling rapid implementation of protective actions. A Genetic Algorithm (GA) is employed to optimize the fitness function, while MATLAB/Simulink is used to model both the generator and its excitation system (ST1A exciter). Simulation results demonstrate that this method significantly outperforms existing approaches in terms of detection speed, accuracy, and reliability. This advancement enhances the protection of synchronous generators against power swing phenomena and other system disturbances, thereby contributing to the robustness and stability of power networks.

Authors

Institutions

Publication Details

Published
2025-06-29
DOI
https://doi.org/10.1109/powertech59965.2025.11180552
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast and Adaptive Loss of Field Detection in Synchronous Generators Using Real-Time Monitoring and Genetic Algorithm

Roozbeh Eshraghnia
Power Systems and Renewable Energy
article

Fast and Adaptive Loss of Field Detection in Synchronous Generators Using Real-Time Monitoring and Genetic Algorithm

Roozbeh Eshraghnia
article en

Abstract

Loss of Field (LOF) is a common fault in synchronous machine operation, often resulting from short circuits in the field winding or inadvertent tripping of the field breaker. Effective protection of synchronous generators against LOF is crucial due to its potential to cause generator and grid instability, reduced operational efficiency, and significant machine damage. This paper presents an advanced method for initiating a trip signal to the Loss of Excitation (LOE) relay in synchronous generators, utilizing real-time data monitoring and adaptive techniques for reliable detection. The proposed method leverages variations in rotor angle, generator voltage, and reactive power to promptly identify LOF conditions, enabling rapid implementation of protective actions. A Genetic Algorithm (GA) is employed to optimize the fitness function, while MATLAB/Simulink is used to model both the generator and its excitation system (ST1A exciter). Simulation results demonstrate that this method significantly outperforms existing approaches in terms of detection speed, accuracy, and reliability. This advancement enhances the protection of synchronous generators against power swing phenomena and other system disturbances, thereby contributing to the robustness and stability of power networks.

Deutscher Verein des Gas und Wasserfaches (DE)
Openalex Percentile: Top 69%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.