A Novel Low-Profile Full-Flow Percutaneous Ventricular Assist Device

Percutaneous ventricular assist devices (pVAD) decrease mortality in cardiogenic shock (CS) patients, but at a high adverse event rate. Novel pVADs need to improve cardiac power output (CPO) to improve efficacy and reduce profile to reduce adverse events. Venstramedical has developed an impeller with nitinol and polymer which can collapse for low-profile insertion and expand in the body to provide optimal CPO. We have also developed a unique 9 French (9Fr) delivery system. In vitro and in vivo testing have been performed to develop this device. Head-flow (HQ) tests generate 5.0 L/min with a pressure differential of 80 mm Hg and 7.0 L/min against 60 mm Hg. Durability testing demonstrated continuous operation of up to 20 days. In the acute healthy ovine model, we demonstrated full flow (7-9 L against 60-80 mm Hg), transcatheter 9Fr delivery, retrieval of the device, and resting of the native heart during pumping. In a CS animal, we demonstrated survival and resting of the native heart during the acute study with decreased stroke work (SW), decreased stroke volume (SV), while total cardiac output was up to 7 L/min and maintaining adequate pressure with low hemolysis. We also demonstrated multiday functioning of the device in a healthy ovine model with good CO and low hemolysis.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-10-03
DOI
https://doi.org/10.1097/mat.0000000000002564
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Low-Profile Full-Flow Percutaneous Ventricular Assist Device

Atta Behfar, S. Thambar, Sara Inglis, Martin J. Cook et al.
ASAIO Journal
Mechanical Circulatory Support Devices
article

A Novel Low-Profile Full-Flow Percutaneous Ventricular Assist Device

Atta Behfar, S. Thambar, Sara Inglis, Martin J. Cook, Jordon Honeck
article en

Abstract

Percutaneous ventricular assist devices (pVAD) decrease mortality in cardiogenic shock (CS) patients, but at a high adverse event rate. Novel pVADs need to improve cardiac power output (CPO) to improve efficacy and reduce profile to reduce adverse events. Venstramedical has developed an impeller with nitinol and polymer which can collapse for low-profile insertion and expand in the body to provide optimal CPO. We have also developed a unique 9 French (9Fr) delivery system. In vitro and in vivo testing have been performed to develop this device. Head-flow (HQ) tests generate 5.0 L/min with a pressure differential of 80 mm Hg and 7.0 L/min against 60 mm Hg. Durability testing demonstrated continuous operation of up to 20 days. In the acute healthy ovine model, we demonstrated full flow (7-9 L against 60-80 mm Hg), transcatheter 9Fr delivery, retrieval of the device, and resting of the native heart during pumping. In a CS animal, we demonstrated survival and resting of the native heart during the acute study with decreased stroke work (SW), decreased stroke volume (SV), while total cardiac output was up to 7 L/min and maintaining adequate pressure with low hemolysis. We also demonstrated multiday functioning of the device in a healthy ovine model with good CO and low hemolysis.

ASAIO Journal
University of Minnesota (US), Mayo Clinic (US), Hunter Water (AU)
Openalex Percentile: Top 73%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.