Comparison of Intubating Conditions for Nasotracheal Intubation with BPL® Video Laryngoscope versus Standard Direct Macintosh Laryngoscope using Cuff Inflation Technique: A Randomised Clinical Study

Introduction: Nasotracheal intubation is required in maxillofacial, oral and dental surgeries and it presents unique anatomical and technical challenges. The Macintosh laryngoscope is a gold standard for nasotracheal intubation but requires alignment of the oral, pharyngeal, and laryngeal axis. Conversely, video laryngoscopy helps in the visualisation of the real-time and enlarged video image of airway structures. Aim: To compare two laryngoscopy techniques- British Physical Laboratories® (BPL) video laryngoscope and Macintosh laryngoscope - using the cuff inflation technique to optimise intubation conditions. Materials and Methods: This randomised clinical single-blinded study was carried out in the Department of Anaesthesiology at Dhiraj Hospital, Smt. B.K. Shah Medical Institute and Research Centre (SBKS) Medical Institute and Research Centre (Deemed to be University), Piparia, Waghodia, Vadodara, Gujarat, India, between September 2023 and May 2025, on 66 adult patients divided into two equal groups. Group V patients underwent BPL® video laryngoscopy with cuff inflation, while group M patients underwent Macintosh laryngoscopy with the same technique. Patients were assessed for intubation time, Cormack–Lehane grading, number of attempts, initial 15 mL cuff inflation success, need of additional 5 mL inflation, need for Magill’s forceps or external laryngeal manipulation, haemodynamic parameters like Heart Rate (HR) and Mean Blood Pressure (MBP) and post-procedural complications. The Unpaired t-test was used for numerical variables, and the Chi-square test was used for categorical variables. A p-value <0.05 was considered statistically significant, and a p-value <0.001 was considered highly important. Results: Both groups were comparable in terms of demographic parameters like age, gender, weight, American Society of Anaesthesiologists (ASA) physical status classification and Mallampati Classification of the airway. Group V demonstrated significantly shorter intubation time (31.51±2.16 seconds vs. 45.97±3.15 seconds, p-value <0.001. Initial cuff inflation was more successful in group V (87.88% vs. 48.48%, p-value <0.001). Need for additional 5 mL inflation (12.12% vs 33.33%, p-value=0.04), need for Magill’s forcep (0% vs 18.18%, p-value=0.01) and external laryngeal manipulation (9.09% vs 36.36%, p-value=0.007) were significantly lower in group V. HR and MBP were significantly lower at laryngoscopy and intubation till 5 minutes post-intubation (p-value <0.05) in Group V. The incidence of sore throat (15.15% vs 54.55%, p-value <0.001) and post-procedure bleeding (12.12% vs. 45.45%, p-value=0.003) was significantly lower in group V. Conclusion: The BPL® video laryngoscope with cuff inflation technique demonstrated superior intubating conditions compared to the standard Macintosh laryngoscope, providing shorter intubation times, higher success with initial 15 mL cuff inflation, better haemodynamic stability, and reduced complication rates during nasotracheal intubation.

Authors

Publication Details

Journal
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
Published
2025-10-08
DOI
https://doi.org/10.7860/jcdr/2025/82411.21967
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Intubating Conditions for Nasotracheal Intubation with BPL® Video Laryngoscope versus Standard Direct Macintosh Laryngoscope using Cuff Inflation Technique: A Randomised Clinical Study

Jigisha Mehta, Sara Mary Thomas, Pooja Shah, Dhananjay Nivrutti Dhasade
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
Airway Management and Intubation Techniques
article

Comparison of Intubating Conditions for Nasotracheal Intubation with BPL® Video Laryngoscope versus Standard Direct Macintosh Laryngoscope using Cuff Inflation Technique: A Randomised Clinical Study

Jigisha Mehta, Sara Mary Thomas, Pooja Shah, Dhananjay Nivrutti Dhasade
article en

Abstract

Introduction: Nasotracheal intubation is required in maxillofacial, oral and dental surgeries and it presents unique anatomical and technical challenges. The Macintosh laryngoscope is a gold standard for nasotracheal intubation but requires alignment of the oral, pharyngeal, and laryngeal axis. Conversely, video laryngoscopy helps in the visualisation of the real-time and enlarged video image of airway structures. Aim: To compare two laryngoscopy techniques- British Physical Laboratories® (BPL) video laryngoscope and Macintosh laryngoscope - using the cuff inflation technique to optimise intubation conditions. Materials and Methods: This randomised clinical single-blinded study was carried out in the Department of Anaesthesiology at Dhiraj Hospital, Smt. B.K. Shah Medical Institute and Research Centre (SBKS) Medical Institute and Research Centre (Deemed to be University), Piparia, Waghodia, Vadodara, Gujarat, India, between September 2023 and May 2025, on 66 adult patients divided into two equal groups. Group V patients underwent BPL® video laryngoscopy with cuff inflation, while group M patients underwent Macintosh laryngoscopy with the same technique. Patients were assessed for intubation time, Cormack–Lehane grading, number of attempts, initial 15 mL cuff inflation success, need of additional 5 mL inflation, need for Magill’s forceps or external laryngeal manipulation, haemodynamic parameters like Heart Rate (HR) and Mean Blood Pressure (MBP) and post-procedural complications. The Unpaired t-test was used for numerical variables, and the Chi-square test was used for categorical variables. A p-value <0.05 was considered statistically significant, and a p-value <0.001 was considered highly important. Results: Both groups were comparable in terms of demographic parameters like age, gender, weight, American Society of Anaesthesiologists (ASA) physical status classification and Mallampati Classification of the airway. Group V demonstrated significantly shorter intubation time (31.51±2.16 seconds vs. 45.97±3.15 seconds, p-value <0.001. Initial cuff inflation was more successful in group V (87.88% vs. 48.48%, p-value <0.001). Need for additional 5 mL inflation (12.12% vs 33.33%, p-value=0.04), need for Magill’s forcep (0% vs 18.18%, p-value=0.01) and external laryngeal manipulation (9.09% vs 36.36%, p-value=0.007) were significantly lower in group V. HR and MBP were significantly lower at laryngoscopy and intubation till 5 minutes post-intubation (p-value <0.05) in Group V. The incidence of sore throat (15.15% vs 54.55%, p-value <0.001) and post-procedure bleeding (12.12% vs. 45.45%, p-value=0.003) was significantly lower in group V. Conclusion: The BPL® video laryngoscope with cuff inflation technique demonstrated superior intubating conditions compared to the standard Macintosh laryngoscope, providing shorter intubation times, higher success with initial 15 mL cuff inflation, better haemodynamic stability, and reduced complication rates during nasotracheal intubation.

JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
Openalex Percentile: Top 55%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.