A compact, all-digital microwave impedance microscopy system with automatic baseline cancellation

We present a compact, fully digitally controlled microwave impedance microscopy (MIM) system implemented on a modular surface-mount platform. The design features a high-resolution, digitally tunable cancellation line that efficiently suppresses baseline reflections via destructive interference, thereby reducing noise and enhancing sensitivity for low baseband frequency or high power measurements. The physics-informed cancellation algorithm rapidly minimizes residual power within few seconds, requiring no manual adjustment. The quasi-DC-coupled readout supports both contact- and tapping-mode MIM imaging without risk of saturation. We validate system performance with high-quality MIM scans and demonstrate near-Johnson-noise-limited noise floor down to 4 kHz baseband frequency with optimal cancellation.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-10-01
DOI
https://doi.org/10.1063/5.0294058
Citations
1
Primary Topic
Near-Field Optical Microscopy
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A compact, all-digital microwave impedance microscopy system with automatic baseline cancellation

Amogh Yogesh Waghmare, Adam Pierce, Yue Ma
1 citations
Review of Scientific Instruments
Near-Field Optical Microscopy
0.67
article

A compact, all-digital microwave impedance microscopy system with automatic baseline cancellation

Amogh Yogesh Waghmare, Adam Pierce, Yue Ma
article en
1 citations

Abstract

We present a compact, fully digitally controlled microwave impedance microscopy (MIM) system implemented on a modular surface-mount platform. The design features a high-resolution, digitally tunable cancellation line that efficiently suppresses baseline reflections via destructive interference, thereby reducing noise and enhancing sensitivity for low baseband frequency or high power measurements. The physics-informed cancellation algorithm rapidly minimizes residual power within few seconds, requiring no manual adjustment. The quasi-DC-coupled readout supports both contact- and tapping-mode MIM imaging without risk of saturation. We validate system performance with high-quality MIM scans and demonstrate near-Johnson-noise-limited noise floor down to 4 kHz baseband frequency with optimal cancellation.

Review of Scientific InstrumentsVol. 96(10)
Lawrence Berkeley National Laboratory (US), University of California, Berkeley (US)
Openalex Percentile: Top 26%
Near-Field Optical Microscopy
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.