Enhanced external counter pulsation as a novel therapy to maintain cardiac output during hemodialysis: a preliminary randomized controlled study

Intradialytic cardiac output (CO) decline normally occurs during hemodialysis (HD) and results in short-term intradialytic hypotension to longer-term increased cardiovascular morbidity and mortality in chronic HD patients. Enhanced external counter pulsation (EECP) is a novel non-invasive device that has been demonstrated to improve coronary blood flow and maintain systemic hemodynamics in patients without kidney dysfunction. This study is the first to explore the efficacy and safety of EECP application during HD on intradialytic changes of CO and other hemodynamic parameters. Stable chronic HD patients without recent cardiovascular events were randomly allocated to the EECP group (n = 7) receiving a single session of 60-min EECP therapy at the early period of 4-h online hemodiafiltration (HDF), and the control group (n = 7) obtaining standard 4-h online HDF without EECP. Interval measurements of intradialytic CO by Transonic HD03 device, intradialytic central aortic blood pressure (BP) by AtCor Medical SphygmoCor-XCEL device, and heart rate (HR) in the mid-week HD sessions were conducted. Changes in these parameters were compared with a linear mixed model. CO of the patients in the EECP group was maintained throughout the HDF session compared to a significant CO decline of 2.4 L/min after 4-h HDF in the control group (p-value 0.007). Cardiac index (CI) also changed in the same direction as CO. Central systolic BP, central diastolic BP, central mean arterial pressure, and HR were indifferent between the two groups. In 9 patients continuing the study in the subsequent 36 HDF sessions, there was a trend to prevent the increase in high-sensitivity cardiac troponin I by long-term EECP treatment. No intolerable adverse events related to EECP were reported. EECP application during online HDF could maintain CO, CI, and might reduce the risk of HD-related myocardial ischemia through various proposed mechanisms, including promoting coronary perfusion. However, larger studies on other cardiovascular outcomes are warranted.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-08
DOI
https://doi.org/10.1038/s41598-025-19077-5
Citations
1
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced external counter pulsation as a novel therapy to maintain cardiac output during hemodialysis: a preliminary randomized controlled study

Khajohn Tiranathanagul, Weerapat Kositanurit, Sarawut Siwamogsatham, Thana Thongsricome et al.
1 citations
Scientific Reports
Dialysis and Renal Disease Management
1.43
article

Enhanced external counter pulsation as a novel therapy to maintain cardiac output during hemodialysis: a preliminary randomized controlled study

Khajohn Tiranathanagul, Weerapat Kositanurit, Sarawut Siwamogsatham, Thana Thongsricome, Yingyos Avihingsanon, Somchit Eiam‐Ong, Somchai Eiam-Ong
article en
1 citations

Abstract

Intradialytic cardiac output (CO) decline normally occurs during hemodialysis (HD) and results in short-term intradialytic hypotension to longer-term increased cardiovascular morbidity and mortality in chronic HD patients. Enhanced external counter pulsation (EECP) is a novel non-invasive device that has been demonstrated to improve coronary blood flow and maintain systemic hemodynamics in patients without kidney dysfunction. This study is the first to explore the efficacy and safety of EECP application during HD on intradialytic changes of CO and other hemodynamic parameters. Stable chronic HD patients without recent cardiovascular events were randomly allocated to the EECP group (n = 7) receiving a single session of 60-min EECP therapy at the early period of 4-h online hemodiafiltration (HDF), and the control group (n = 7) obtaining standard 4-h online HDF without EECP. Interval measurements of intradialytic CO by Transonic HD03 device, intradialytic central aortic blood pressure (BP) by AtCor Medical SphygmoCor-XCEL device, and heart rate (HR) in the mid-week HD sessions were conducted. Changes in these parameters were compared with a linear mixed model. CO of the patients in the EECP group was maintained throughout the HDF session compared to a significant CO decline of 2.4 L/min after 4-h HDF in the control group (p-value 0.007). Cardiac index (CI) also changed in the same direction as CO. Central systolic BP, central diastolic BP, central mean arterial pressure, and HR were indifferent between the two groups. In 9 patients continuing the study in the subsequent 36 HDF sessions, there was a trend to prevent the increase in high-sensitivity cardiac troponin I by long-term EECP treatment. No intolerable adverse events related to EECP were reported. EECP application during online HDF could maintain CO, CI, and might reduce the risk of HD-related myocardial ischemia through various proposed mechanisms, including promoting coronary perfusion. However, larger studies on other cardiovascular outcomes are warranted.

Scientific ReportsVol. 15(1)
Thai Red Cross Society (TH), Chulalongkorn University (TH), King Chulalongkorn Memorial Hospital (TH)
Chulalongkorn University, Faculty of Medicine, Chulalongkorn University
Openalex Percentile: Top 15%
Dialysis and Renal Disease Management
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.