Low-dose cone-beam CT for gastric volumetry in endoscopic sleeve gastroplasty

The study aimed to evaluate the feasibility of using cone-beam computed tomography (CBCT) for gastric volume assessment before and after endoscopic sleeve gastroplasty (ESG), focusing on patient radiation dose. Ten patients scheduled for ESG were prospectively enrolled. Each patient underwent three CBCT scans under anesthesia: two scans following CO<sub>2</sub> insufflation of the gastric lumen-one pre-ESG and one post-ESG-and a third scan post-ESG after gastric distension with Gastrografin. Image quality was evaluated for its adequacy in generating three-dimensional reconstructions and calculating gastric volumes. Dose-area product was recorded for each scan and used to estimate the effective dose (ED) via Monte Carlo simulations using the PCXMC rotational model. Although image quality did not match conventional computed tomography (CT), it was sufficient for three-dimensional reconstruction and gastric volume measurements. The median ED was 4.2 mSv for pre-ESG scans with CO<sub>2</sub> insufflation, 4.2 mSv for post-ESG scans with CO2 insufflation, and 4.8 mSv for post-ESG scans with Gastrografin. CBCT provided satisfactory image quality for gastric volumetry at relatively low radiation doses, with ED being approximately 50% of that of conventional CT. This preliminary feasibility study suggests that CBCT could be a useful tool for planning ESG and assessing post-procedural outcomes. RELEVANCE STATEMENT: Low-dose CBCT provided sufficient image quality for gastric volumetry in a small cohort of patients undergoing ESG, reducing radiation exposure by approximately 50% compared to conventional CT. This investigational technique enables seamless intraoperative imaging that could improve planning and evaluation of endoscopic bariatric procedures. KEY POINTS: CBCT allowed gastric volumetric assessment at a relatively low radiation dose. Scans with CO<sub>2</sub> insufflation delivered lower radiation doses than scans with Gastrografin. Scans with CO<sub>2</sub> insufflation showed superior image quality compared to scans with Gastrografin. CBCT could be a valuable tool for planning ESG and evaluating outcomes.

Authors

Institutions

Publication Details

Journal
European Radiology Experimental
Published
2025-10-07
DOI
https://doi.org/10.1186/s41747-025-00637-3
Primary Topic
Bariatric Surgery and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-dose cone-beam CT for gastric volumetry in endoscopic sleeve gastroplasty

Cristiano Spada, Evis Sala, Ivo Boškoski, Andrea Morasca et al.
European Radiology Experimental
Bariatric Surgery and Outcomes
article

Low-dose cone-beam CT for gastric volumetry in endoscopic sleeve gastroplasty

Cristiano Spada, Evis Sala, Ivo Boškoski, Andrea Morasca, Valerio Pontecorvi, Ilaria Nacci, Roberto Moretti
article en

Abstract

The study aimed to evaluate the feasibility of using cone-beam computed tomography (CBCT) for gastric volume assessment before and after endoscopic sleeve gastroplasty (ESG), focusing on patient radiation dose. Ten patients scheduled for ESG were prospectively enrolled. Each patient underwent three CBCT scans under anesthesia: two scans following CO<sub>2</sub> insufflation of the gastric lumen-one pre-ESG and one post-ESG-and a third scan post-ESG after gastric distension with Gastrografin. Image quality was evaluated for its adequacy in generating three-dimensional reconstructions and calculating gastric volumes. Dose-area product was recorded for each scan and used to estimate the effective dose (ED) via Monte Carlo simulations using the PCXMC rotational model. Although image quality did not match conventional computed tomography (CT), it was sufficient for three-dimensional reconstruction and gastric volume measurements. The median ED was 4.2 mSv for pre-ESG scans with CO<sub>2</sub> insufflation, 4.2 mSv for post-ESG scans with CO2 insufflation, and 4.8 mSv for post-ESG scans with Gastrografin. CBCT provided satisfactory image quality for gastric volumetry at relatively low radiation doses, with ED being approximately 50% of that of conventional CT. This preliminary feasibility study suggests that CBCT could be a useful tool for planning ESG and assessing post-procedural outcomes. RELEVANCE STATEMENT: Low-dose CBCT provided sufficient image quality for gastric volumetry in a small cohort of patients undergoing ESG, reducing radiation exposure by approximately 50% compared to conventional CT. This investigational technique enables seamless intraoperative imaging that could improve planning and evaluation of endoscopic bariatric procedures. KEY POINTS: CBCT allowed gastric volumetric assessment at a relatively low radiation dose. Scans with CO<sub>2</sub> insufflation delivered lower radiation doses than scans with Gastrografin. Scans with CO<sub>2</sub> insufflation showed superior image quality compared to scans with Gastrografin. CBCT could be a valuable tool for planning ESG and evaluating outcomes.

European Radiology ExperimentalVol. 9(1)
Agostino Gemelli University Polyclinic (IT)
Fondazione Roma
Openalex Percentile: Top 56%
Bariatric Surgery and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines