Evaluation of a CdTe semiconductor‐based gamma camera for real‐time dose dosimetry in boron neutron capture therapy

This study demonstrates that a CdTe-DSD-based gamma camera is a promising tool for real-time boron dosimetry in BNCT. The detector's high energy resolution and excellent spatial resolution enable precise detection of 478 keV prompt <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:semantics><mml:mi>γ</mml:mi> <mml:annotation>$\gamma$</mml:annotation></mml:semantics> </mml:math> -rays, facilitating accurate mapping of boron distribution during neutron irradiation. These findings support the developed system's potential to enhance BNCT treatment planning and patient-specific dose monitoring. Future research will optimize neutron shielding and explore advanced collimator designs to improve sensitivity in clinical settings.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-10-01
DOI
https://doi.org/10.1002/mp.70062
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a CdTe semiconductor‐based gamma camera for real‐time dose dosimetry in boron neutron capture therapy

Shin׳ichiro Takeda, Tadayuki Takahashi, Takahito Osawa, Kazuhiko Ninomiya et al.
1 citations
Medical Physics
Radiation Detection and Scintillator Technologies
1.88
article

Evaluation of a CdTe semiconductor‐based gamma camera for real‐time dose dosimetry in boron neutron capture therapy

Shin׳ichiro Takeda, Tadayuki Takahashi, Takahito Osawa, Kazuhiko Ninomiya, Takehiro Sumita, I. Chiu
article en
1 citations

Abstract

This study demonstrates that a CdTe-DSD-based gamma camera is a promising tool for real-time boron dosimetry in BNCT. The detector's high energy resolution and excellent spatial resolution enable precise detection of 478 keV prompt <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:semantics><mml:mi>γ</mml:mi> <mml:annotation>$\gamma$</mml:annotation></mml:semantics> </mml:math> -rays, facilitating accurate mapping of boron distribution during neutron irradiation. These findings support the developed system's potential to enhance BNCT treatment planning and patient-specific dose monitoring. Future research will optimize neutron shielding and explore advanced collimator designs to improve sensitivity in clinical settings.

Medical PhysicsVol. 52(10)
Hiroshima University (JP), Japan Atomic Energy Agency (JP), Kyushu University (JP), High Energy Accelerator Research Organization (JP), Fukushima College (JP), Kavli Institute for the Physics and Mathematics of the Universe (JP), Kyushu International University (JP), Fukushima University (JP), The University of Tokyo (JP)
Japan Society for the Promotion of Science, Japan Atomic Energy Agency
Openalex Percentile: Top 12%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of a CdTe semiconductor‐based gamma camera for real‐time dose dosimetry in boron neutron capture therapy — Shin׳ichiro Takeda, Tadayuki Takahashi, et al. · Medical Physics (2025) | TGRS Research Map | TGRS